AD9991KCP Analog Devices Inc, AD9991KCP Datasheet - Page 33

IC CCD SIGNAL PROCESSOR 56-LFCSP

AD9991KCP

Manufacturer Part Number
AD9991KCP
Description
IC CCD SIGNAL PROCESSOR 56-LFCSP
Manufacturer
Analog Devices Inc
Type
CCD Signal Processor, 10-Bitr
Datasheet

Specifications of AD9991KCP

Rohs Status
RoHS non-compliant
Input Type
Logic
Output Type
Logic
Interface
3-Wire Serial
Mounting Type
Surface Mount
Package / Case
56-LFCSP
Analog Front End Type
CCD
Analog Front End Category
Video
Interface Type
Serial (3-Wire)
Input Voltage Range
0.5V
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (typ)
3V
Operating Supply Voltage (max)
3.6V
Resolution
10b
Number Of Adc's
1
Power Supply Type
Analog/Digital
Operating Temp Range
-20C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
56
Package Type
LFCSP EP
Number Of Channels
1
Current - Supply
-
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9991KCP
Manufacturer:
ADI
Quantity:
246
Part Number:
AD9991KCPZ
Manufacturer:
ADI
Quantity:
244
Part Number:
AD9991KCPZ-RL
Manufacturer:
FUJISU
Quantity:
4 000
(OUTPUT)
(OUTPUT)
OUTPUTS
POWER-UP AND SYNCHRONIZATION
Recommended Power-Up Sequence for Master Mode
When the AD9991 is powered up, the following sequence is
recommended (refer to Figure 35 for each step). Note that a
SYNC signal is required for master mode operation. If an exter-
nal SYNC pulse is not available, it is also possible generate an
internal SYNC pulse by writing to the SYNCPOL register, as
described in the next section.
10. Confi gure the AD9991 for Master mode timing by writing a
REV. 0
DIGITAL
WRITES
1. Turn on power supplies for AD9991.
2. Apply the master clock input CLI.
3. Reset the internal AD9991 registers by writing a 1 to the
5. Write a 1 to the BANKSELECT register (addr 0x7F). This
(INPUT)
(INPUT)
SERIAL
(INPUT)
4. By default, the AD9991 is in Standby3 mode. To place the
6. Load Bank 2 registers with the required VPAT group,
7. Write a 0 to the BANKSELECT register to select Bank 1.
8. By default, the internal timing core is held in a reset state with
9. Load the required registers to confi gure the high speed tim-
SYNC
VDD
SW_RESET register (addr 0x10 in Bank 1).
part into normal power operation, write 0x004 to the AFE
OPRMODE register (addr 0x00 in Bank 1).
will select Register Bank 2.
V-sequence, and fi eld timing information.
TGCORE_RSTB register = 0. Write a 1 to the TGCORE_
RSTB register (addr 0x15 in Bank 1) to start the internal
timing core operation.
ing, horizontal timing, and shutter timing information.
1 to the MASTER register (addr 0x20 in Bank 1).
CLI
HD
VD
t
PWR
H1/H3, RG, DCLK
H2/H4
Figure 35. Recommended Power-Up Sequence and Synchronization, Master Mode
–33–
11. Write a 1 to the OUT_CONTROL register (addr 0x11 in
12. Generate a SYNC event: If SYNC is high at power-up, bring
Address
0x10
0x00
0x7F
0x00–0xFF
0x7F
0x15
0x30–71
0x20
0x11
0x13
Generating Software SYNC without External SYNC Signal
If an external SYNC pulse is not available, it is possible to
generate an internal SYNC in the AD9991 by writing to the
SYNCPOL register (addr 0x13). If the software SYNC option is
used, the SYNC input (Pin 46) should be tied to ground (VSS).
After power-up, follow the same procedure as before for Steps
1–11. Then, for Step 12, instead of using the external SYNC
pulse, write a 1 to the SYNCPOL register. This will generate the
SYNC internally, and timing operation will begin.
Bank 1). This will allow the outputs to become active after
the next SYNC rising edge.
the SYNC input low for a minimum of 100 ns. Then bring
SYNC back high. This will cause the internal counters to
reset and will start VD/HD operation. The fi rst VD/HD edge
allows most Bank 1 register updates to occur, including
OUT_CONTROL to enable all outputs.
Table XIII. Power-Up Register Write Sequence
t
SYNC
Data
0x01
0x04
0x01
0x00
0x01
0x01
0x01
0x01
VPAT, V-Sequence, and Field Timing
1 H
Description
Reset All Registers to Default Values
Power Up the AFE and CLO Oscillator
Select Register Bank 2
Select Register Bank 1
Reset Internal Timing Core
Horizontal and Shutter Timing
Confi gure for Master Mode
Enable All Outputs after SYNC
SYNCPOL (for Software SYNC Only)
1ST FIELD
CLOCKS ACTIVE WHEN OUT_CONTROL
REGISTER IS UPDATED AT VD/HD EDGE
1V
AD9991