GRM1885C1H101J Murata, GRM1885C1H101J Datasheet - Page 84

GRM1885C1H101J

Manufacturer Part Number
GRM1885C1H101J
Description
Manufacturer
Murata
Datasheet

Specifications of GRM1885C1H101J

Capacitance
100pF
Tolerance (+ Or -)
5%
Voltage
50VDC
Temp Coeff (dielectric)
C0G
Operating Temp Range
-55C to 125C
Mounting Style
Surface Mount
Package / Case
0603
Construction
SMT Chip
Case Style
Ceramic Chip
Failure Rate
Not Required
Wire Form
Not Required
Product Length (mm)
1.6mm
Product Depth (mm)
0.8mm
Product Height (mm)
0.8mm
Product Diameter (mm)
Not Requiredmm
Dc
07+
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
GRM1885C1H101JA01D
Manufacturer:
MURATA
Quantity:
640 000
Part Number:
GRM1885C1H101JA01D
Manufacturer:
MURATA
Quantity:
208 000
Part Number:
GRM1885C1H101JA01J
Manufacturer:
MURATA
Quantity:
170 000
3
!Note
• This PDF catalog is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our
• This PDF catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
sales representatives or product engineers before ordering.
!Note
82
No.
14
15
16
17
LLL/LLA/LLM Series Specifications and Test Methods (1)
LLL/LLA/LLM Series Specifications and Test Methods (1)
Continued from the preceding page.
Temperature
Cycle
Humidity
(Steady
Humidity
Load
High
Temperature
Load
State)
• Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
Item
Appearance
Capacitance
Change
D.F.
I.R.
Dielectric
Strength
Appearance
Capacitance
Change
D.F.
I.R.
Appearance
Capacitance
Change
D.F.
I.R.
Appearance
Capacitance
Change
D.F.
I.R.
No marking defects
Within T7.5%
W.V.: 25V min.; 0.025 max.
W.V.: 16V/10V max.; 0.035 max.
W.V.: 6.3V max.; 0.05 max.
More than 10,000MΩ or 500Ω · F (Whichever is smaller)
No failure
No marking defects
Within T12.5%
W.V.: 10V min.; 0.05 max.
W.V.: 6.3V max.; 0.075 max.
More than 1,000MΩ or 50Ω · F (Whichever is smaller)
No marking defects
Within T12.5%
W.V.: 10V min.; 0.05 max.
W.V.: 6.3V max.; 0.075 max.
More than 500MΩ or 25Ω · F
(Whichever is smaller)
No marking defects
Within T12.5%
W.V.: 10V min.; 0.05 max.
W.V.: 6.3V max.; 0.075 max.
More than 1,000MΩ or 50Ω · F
(Whichever is smaller)
In case Non "*" is added in PNs table, please refer to LLL/LLA/LLM Series Specifications and Test Methods (1).
In case "*" is added in PNs table, please refer to LLL/LLA/LLM Series Specifications and Test Methods (2).
Specifications
Fix the capacitor to the supporting jig in the same manner and
under the same conditions as (10).
Perform the five cycles according to the four heat treatments
listed in the following table. Let sit for 24T2 hours at room
temperature, then measure.
• Initial measurement.
Sit the capacitor at 40T2°C and 90 to 95% humidity for 500T12
hours. Remove and let sit for 24T2 hours at room temperature,
then measure.
Apply the rated voltage at 40T2°C and 90 to 95% humidity for
500T12 hours. Remove and let sit for 24T2 hours at room
temperature, then measure. The charge/discharge current is
less than 50mA.
Apply 200% of the rated voltage for 1000T12 hours at the
maximum operating temperature T3°C. Let sit for 24T2 hours
at room temperature, then measure. The charge/discharge
current is less than 50mA.
•Initial measurement.
Perform a heat treatment at 150
let sit for 24T2 hours at room temperature. Perform the initial
measurement.
Apply 200% of the rated DC voltage for one hour at the
maximum operating temperature T3°C. Remove and let sit for
24T2 hours at room temperature.
Perform initial measurement.
Temp. (°C)
Time (min.)
Step
Min. Operating
Temp.
30T3
1
+0
–3
Test Method
Temp.
Room
2 to 3
2
+0
–10
°C for one hour and then
Max. Operating
Temp.
30T3
3
+3
–0
Temp.
Room
2 to 3
4
C02E.pdf
09.9.18

Related parts for GRM1885C1H101J