PSB 2132 H V2.2 Infineon Technologies, PSB 2132 H V2.2 Datasheet - Page 33

IC CODEC FILTER 2CHAN MQFP-64

PSB 2132 H V2.2

Manufacturer Part Number
PSB 2132 H V2.2
Description
IC CODEC FILTER 2CHAN MQFP-64
Manufacturer
Infineon Technologies
Series
SICOFI®r
Datasheet

Specifications of PSB 2132 H V2.2

Package / Case
64-QFP
Function
CODEC Filter
Interface
IOM-2 PCM, SPI
Number Of Circuits
2
Voltage - Supply
5V
Current - Supply
18mA
Power (watts)
90mW
Mounting Type
Surface Mount
Includes
Level Metering Function, Tone Generation
Number Of Adc Inputs
2
Number Of Dac Outputs
2
Interface Type
Serial
Operating Supply Voltage
5 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
0 C
Number Of Channels
2
Snr
35.4 dB
Supply Current
40 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
PSB2132HV2.2XT
SP000007696
Figure 13
4.2.18
The quality of Transhybrid-Balancing is very sensitive to deviations in gain, group delay,
and deviations inherent to the A/D- and D/A-converters, as well as to all external
components used with a tip/ring interface (SLIC, OP’s etc.).
Transhybrid loss test setup:
The SICOFI
analog output with the analog input. The programmable filters FRR, AR, FRX, AX are
by-passed. The IM-filter is disabled, (H(IM)=0). The balancing filter TH is enabled with
optimized coefficients for this configuration (
A 0 dBm0 sine wave signal with a frequency in the range of 300 Hz to 3400 Hz is applied
to the digital input. The signal levels of the resulting echo at the digital output will stay
below the values shown in Table 20.
Table 20
Hardware Reference Manual
Input Frequency
2500 Hz
3000 Hz
3400 Hz
300 Hz
500 Hz
dBm0
-100
Transhybrid Loss
-40
-50
-55
-60
-70
-78
-80
-90
®
2-TE test loop “DLB-ANA” is selected (see Figure 31), which connects the
10
Analog Output: Out-of-Band Idle Channel Noise
Transhybrid Loss
1
Symbol
THL
THL
THL
THL
THL
2500
3000
3400
300
500
Transhybrid Loss
10
min.
19
25
21
19
19
2
24
V
OUT
typ.
40
45
40
35
35
=
V
IN
10
).
Unit
dB
dB
dB
dB
dB
3
Operational Description
T
AGX = AGR = 0 dB;
typical variation of
amplitude:
delay:
A
= 25 C;
f
Test Condition
kHz
0.5 µs.
V
10
0.15 dB
PSB 2132
DD
4
2001-02-20
= 5 V
2132_216