SAM7S32 Atmel Corporation, SAM7S32 Datasheet - Page 362

no-image

SAM7S32

Manufacturer Part Number
SAM7S32
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7S32

Flash (kbytes)
32 Kbytes
Pin Count
48
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
21
Ext Interrupts
21
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Uart
2
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
8
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
Table 31-2.
31.6.1.3
362
Source Clock
12 000 000
12 288 000
14 318 180
14 745 600
18 432 000
24 000 000
24 576 000
25 000 000
32 000 000
32 768 000
33 000 000
40 000 000
50 000 000
8 000 000
SAM7S Series
SAM7S512/156/128 Fractional Baud Rate in Asynchronous Mode
Baud Rate Example (OVER = 0) (Continued)
Expected Baud
The baud rate is calculated with the following formula:
The baud rate error is calculated with the following formula. It is not recommended to work with
an error higher than 5%.
The Baud Rate generator previously defined is subject to the following limitation: the output fre-
quency changes by only integer multiples of the reference frequency. An approach to this
problem is to integrate a fractional N clock generator that has a high resolution. The generator
architecture is modified to obtain Baud Rate changes by a fraction of the reference source clock.
This fractional part is programmed with the FP field in the Baud Rate Generator Register
(US_BRGR). If FP is not 0, the fractional part is activated. The resolution is one eighth of the
clock divider. This feature is only available when using USART normal mode. The fractional
Baud Rate is calculated using the following formula:
The modified architecture is presented below:
Baudrate
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
Rate
BaudRate
Error
=
=
1
------------------------------------------------------------------
8 2 Over
Calculation Result
(
=
ExpectedBaudRate
-------------------------------------------------------- -
SelectedClock
ActualBaudRate
MCK
13.02
19.53
20.00
23.30
24.00
30.00
39.06
40.00
40.69
52.08
53.33
53.71
65.10
81.38
) CD
CD
+
×
FP
------- -
8
16
CD
13
20
20
23
24
30
39
40
40
52
53
54
65
81
Actual Baud Rate
38 461.54
37 500.00
38 400.00
38 908.10
38 400.00
38 400.00
38 461.54
38 400.00
38 109.76
38 461.54
38 641.51
38 194.44
38 461.54
38 580.25
6175L–ATARM–28-Jul-11
0.16%
2.40%
0.00%
1.31%
0.00%
0.00%
0.16%
0.00%
0.76%
0.16%
0.63%
0.54%
0.16%
0.47%
Error

Related parts for SAM7S32