SAM9XE512 Atmel Corporation, SAM9XE512 Datasheet - Page 843

no-image

SAM9XE512

Manufacturer Part Number
SAM9XE512
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM9XE512

Flash (kbytes)
512 Kbytes
Pin Count
217
Max. Operating Frequency
180 MHz
Cpu
ARM926
Hardware Qtouch Acquisition
No
Max I/o Pins
96
Ext Interrupts
96
Usb Transceiver
3
Usb Speed
Full Speed
Usb Interface
Host, Device
Spi
2
Twi (i2c)
2
Uart
6
Ssc
1
Ethernet
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
Yes
Adc Channels
4
Adc Resolution (bits)
10
Adc Speed (ksps)
312
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
NO
External Bus Interface
1
Dram Memory
sdram
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.65 to 1.95
Fpu
No
Mpu / Mmu
No / Yes
Timers
6
Output Compare Channels
6
Input Capture Channels
6
32khz Rtc
Yes
Calibrated Rc Oscillator
No
46.2.9.3
46.2.10
46.2.10.1
46.2.10.2
6254C–ATARM–22-Jan-10
Universal Synchronous Asycnchronous Receiver Transmitter (USART)
UHP: Remote Wakeup Event
USART: Slave Synchronous Mode
USART: Number of Errors Register (US_NER) ISO7816 error number
Consequence: After the failure condition, the Host controller stops sending the SOF. This
causes the connected device to go into suspend state.
This problem can be avoided if the system can guarantee that no buffer underrun occurs during
the transfer.
Conditions:
When a Remote Wakeup event occurs on a downstream port, the OHCI Host controller begins
sending resume signaling to the device. The Host controller is supposed to send this resume
signaling for 20 ms. However, if the driver sets the HcControl, HCFS into USBOPERATIONAL
state during the resume event, then the Host controller terminates sending the resume signal
with an EOP to the device.
Consequence: If the Device does not recognize the resume (<20 ms) event, then the Device will
remain in suspend state.
Host stack can do a port resume after it sets the HcControl, HCFS to USBOPERATIONAL.
Limitation on synchronous mode external clock is MCK/9.
None.
The Number of Errors Register always returns 0 instead of the ISO7816 error number.
It is not part of the ISO7816 protocol.
None.
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
AT91SAM9XE128/256/512 Preliminary