atmega32u4-16mu ATMEL Corporation, atmega32u4-16mu Datasheet - Page 377

no-image

atmega32u4-16mu

Manufacturer Part Number
atmega32u4-16mu
Description
Atmega32u4 8-bit Avr Microcontroller With 32k Bytes Of Isp Flash And Usb Controller
Manufacturer
ATMEL Corporation
Datasheet
29.6.12
29.6.13
29.6.14
7766A–AVR–03/08
Reading the Fuse and Lock Bits
Reading the Signature Bytes
Reading the Calibration Byte
The algorithm for reading the Fuse and Lock bits is as follows (refer to
on page 372
Figure 29-6. Mapping Between BS1, BS2 and the Fuse and Lock Bits During Read
The algorithm for reading the Signature bytes is as follows (refer to
page 372
The algorithm for reading the Calibration byte is as follows (refer to
page 372
1. A: Load Command “0000 0100”.
2. Set OE to “0”, and BS2, BS1 to “00”. The status of the Fuse Low bits can now be read
3. Set OE to “0”, and BS2, BS1 to “11”. The status of the Fuse High bits can now be read
4. Set OE to “0”, and BS2, BS1 to “10”. The status of the Extended Fuse bits can now be
5. Set OE to “0”, and BS2, BS1 to “01”. The status of the Lock bits can now be read at
6. Set OE to “1”.
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte (0x00 - 0x02).
3. Set OE to “0”, and BS to “0”. The selected Signature byte can now be read at DATA.
4. Set OE to “1”.
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte, 0x00.
3. Set OE to “0”, and BS1 to “1”. The Calibration byte can now be read at DATA.
4. Set OE to “1”.
at DATA (“0” means programmed).
at DATA (“0” means programmed).
read at DATA (“0” means programmed).
DATA (“0” means programmed).
for details on Command and Address loading):
for details on Command and Address loading):
for details on Command loading):
Fuse Low Byte
Extended Fuse Byte
Fuse High Byte
Lock Bits
BS2
BS2
0
1
0
1
BS1
0
1
“Programming the Flash” on
“Programming the Flash” on
ATmega32U4
“Programming the Flash”
DATA
377