MPC8360E-RDK Freescale Semiconductor, MPC8360E-RDK Datasheet - Page 40

BOARD REFERENCE DESIGN FOR MPC

MPC8360E-RDK

Manufacturer Part Number
MPC8360E-RDK
Description
BOARD REFERENCE DESIGN FOR MPC
Manufacturer
Freescale Semiconductor
Series
PowerQUICC II™ PROr
Type
MPUr
Datasheets

Specifications of MPC8360E-RDK

Contents
Board, Cables, CD, Power Supply
Processor To Be Evaluated
MPC8360E
Data Bus Width
32 bit
Interface Type
RS-232, Ethernet, USB
Operating Supply Voltage
1.3 V
For Use With/related Products
MPC8360E
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
UCC Ethernet Controller: Three-Speed Ethernet, MII Management
8.3.2
Table 37
40
At recommended operating conditions with LV
Input low voltage
Input current
MDC frequency
MDC period
MDC clock pulse width high
MDC to MDIO delay
MDIO to MDC setup time
MDIO to MDC hold time
MDC rise time
MDC fall time
Notes:
1. The symbols used for timing specifications follow the pattern of t
2. This parameter is dependent on the csb_clk speed (that is, for a csb_clk of 267 MHz, the maximum frequency is 8.3 MHz
3. This parameter is dependent on the ce_clk speed (that is, for a ce_clk of 200 MHz, the delay is 90 ns and for a ce_clk of
inputs and t
data timing (MD) for the time t
Also, t
(V) relative to the t
convention is used with the appropriate letter: R (rise) or F (fall).
and the minimum frequency is 1.2 MHz; for a csb_clk of 375 MHz, the maximum frequency is 11.7 MHz and the minimum
frequency is 1.7 MHz).
300 MHz, the delay is 63 ns).
MPC8360E/MPC8358E PowerQUICC II Pro Processor Revision 2.x TBGA Silicon Hardware Specifications, Rev. 4
Table 36. MII Management DC Electrical Characteristics When Powered at 3.3 V (continued)
MDRDVKH
Parameter/Condition
provides the MII management AC timing specifications.
Parameter
MII Management AC Electrical Specifications
(first two letters of functional block)(reference)(state)(signal)(state)
symbolizes management data timing (MD) with respect to the time data input signals (D) reach the valid state
MDC
clock reference (K) going to the high (H) state or setup time. For rise and fall times, the latter
Table 37. MII Management AC Timing Specifications
MDC
from clock reference (K) high (H) until data outputs (D) are invalid (X) or data hold time.
Symbol
DD
V
I
IN
IL
is 3.3 V ± 10%.
t
t
t
t
Symbol
MDTKHDX
MDTKHDV
MDRDVKH
MDRDXKH
t
t
t
f
t
MDCH
MDCR
MDHF
MDC
MDC
1
0 V ≤ V
Conditions
IN
Min
for outputs. For example, t
(first two letters of functional block)(signal)(state)(reference)(state)
32
10
10
≤ OV
0
DD
Typ
400
2.5
Min
MDKHDX
Max
110
10
10
symbolizes management
Freescale Semiconductor
Max
0.80
±10
MHz
Unit
ns
ns
ns
ns
ns
ns
ns
Notes
Unit
μA
for
V
2
3

Related parts for MPC8360E-RDK