X8-A11-E-A Digi International, X8-A11-E-A Datasheet - Page 144

no-image

X8-A11-E-A

Manufacturer Part Number
X8-A11-E-A
Description
CONNECTPORT X8 2.4GHZ
Manufacturer
Digi International
Series
ConnectPort™ X8r
Datasheets

Specifications of X8-A11-E-A

Function
Transceiver, Xbee, Gateway
Modulation Or Protocol
UDP/TCP, DHCP, SNMPv1
Frequency
2.4GHz
Applications
General Purpose
Interface
RJ45, DB-9, 2 USB
Sensitivity
-93dBm
Power - Output
15dBm
Data Rate - Maximum
54Mbps
Voltage - Supply
12VDC
Wireless Frequency
2.4 GHz
Interface Type
RS-232, Ethernet, USB
Modulation
BPSK, CCK, DBPSK, DQPSK, QPSK
Security
256 bit AES, 3DES, DES, SSL Tunnel
Operating Voltage
9 V to 30 V
Output Power
3.1 W
Antenna
4 in Dipole with 2 ft Cable
Operating Temperature Range
- 30 C to + 60 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
602-1171
TCP and UDP network port numbering conventions
Digi devices use these conventions for TCP and UDP network port numbering.
Ensure that the application or Digi device that initiates communication with the uses these network
ports numbers. If they cannot be configured to use these network port numbers, change the
network port on the Digi device.
UDP Sockets profile
The UDP Sockets profile allows serial devices to communicate using UDP. The UDP Server
configuration allows the serial port to receive data from one or more systems or devices on the
network. The UDP Client configuration allows the automatic distribution of serial data from one
host to many devices at the same time using UDP sockets.
The port numbering conventions shown in the TCP Sockets Profile also apply to UDP sockets.
Serial Bridge profile
The Serial Bridge profile configures one side of a serial bridge. A serial bridge connects two serial
devices over the network, each of which uses a Digi device, as if they were connected with a serial
cable. The serial devices “think” they are communicating with each other across a serial cable
using serial communication techniques. There is no need to reconfigure the server or the serial
device. Neither is aware of the intervening network. Serial bridging is also known as
serial tunneling.
This profile configures each side of the bridge separately. Repeat the configuration for the second
Digi device of the bridge, specifying the IP address of the first Digi device.
Telnet to the serial port
Raw connection to the serial port
For this connection type...
2101(TCP and UDP)
2001 (TCP only)
Use this Port
C o n f i g u r e D i g i d e v i c e s
1 4 4

Related parts for X8-A11-E-A