XTOB001CC1 EATON CUTLER HAMMER, XTOB001CC1 Datasheet - Page 11

Overload Relay

XTOB001CC1

Manufacturer Part Number
XTOB001CC1
Description
Overload Relay
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTOB001CC1

Overload Adjustment Current Min
0.6A
Overload Adjustment Current Max
1A
Coil Voltage Dc Max
220V
Contactor Direction
Non Reversing
Coil Voltage Vdc Nom
220V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
March 2009
Table 34-20. Relays and Timers — Technical Data and Specifications (Continued)
Contacts (Continued)
Magnet Systems
CA08102001E
Description
DC-13
Control circuit reliability
Conventional thermal current (I th )
Short-circuit rating without welding
Current heat losses at load of I th
Pick-up and drop-out values
Power consumption
Duty factor (% DF)
Switching times at 100% U c (approximate values)
DC13 L/R ≤ 15 mS
DC-13 L/R ≤ 50 mS
(at U e = 24V DC, U min = 17, I min = 5.4 mA)
Maximum overcurrent protective device
Short-circuit protection, max. fuse
AC operated (W)
DC operated (W)
AC operated
DC operated
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
Dual-frequency coil 50/60 Hz at 50 Hz
Dual-frequency coil 50/60 Hz at 60 Hz
DC operated
AC operated closing delay (mS)
AC operated NO contact opening delay (mS)
AC operated with auxiliary contact module, max. closing delay (mS)
DC operated closing delay (mS)
DC operated NO contact opening delay (mS)
DC operated with auxiliary contact module, max. closing delay (mS)
Making and breaking conditions to DC13, time constant as stated.
Smoothed DC or three-phase bridge rectifier.
Contacts in series:
Contacts in series:
220/240V – XTPR Frame B
380/415V – XTPR Frame B
500V (A gG/gL)
500V (A fast)
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz (Pick-up x U c )
Dual-frequency coil 50/60 Hz (Pick-up x U c )
Pick -up voltage (Pick-up x U c )
At 24V: without auxiliary contact module (40°C) (Pick-up x U c )
Pick-up VA
Pick-up W
Sealing VA
Sealing W
Pick-up VA
Pick-up W
Sealing VA
Sealing W
Pick-up VA
Pick-up W
Sealing VA
Sealing W
Pull-in = sealing (W)
1
1
2
1
3
1
3
3
3
3
3
Voltage:
Voltage:
110V
110V
220V
220V
110V
220V
24V
60V
60V
24V
60V
For more information visit: www.eaton.com
IEC Contactors & Starters
XT IEC Power Control
Relays and Timers
XTRE
Failure rate = <10
16
4
4
10
0.3
0.3
0.8 – 1.1
0.8 – 1.1
0.8 – 1.1
0.7 – 1.3
24
19
3.4
1.2
27
22
4.2
1.4
25
21
3.3
1.2
3
100
≤21
≤18
≤31
≤12
10
10
4
4
2
1
6
3
6
1
5
in 100 million operations
XTCEXFAC_
10
10
-8
16
10
0.3
0.3
6
3
6
1
5
, < one failure
XTCEXTE_
6
6
0.85 – 11
0.7 – 1.2
2
1.8
100
XTRM
2.5
2.5
1.5
0.5
Failure rate = <10
10
4
4
6
10
0.2
0.3
0.8 – 1.1
0.85 – 1.1
0.85 – 1.3
0.7 – 1.3
25
22
4.6
1.3
30
26
5.4
1.6
29
24
3.9
1.2
2.6
100
14 – 21
45
26 – 35
15 – 25
70
8 – 18
in 100 million operations
XTMCXFA_
2.5
2.5
1.5
0.5
-8
10
4
4
6
10
0.2
0.3
45
70
, < one failure
34-11
34

Related parts for XTOB001CC1