Overload Relay

XTOB001CC1

Manufacturer Part Number
XTOB001CC1
Description
Overload Relay
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTOB001CC1

Overload Adjustment Current Min
0.6A
Overload Adjustment Current Max
1A
Coil Voltage Dc Max
220V
Contactor Direction
Non Reversing
Coil Voltage Vdc Nom
220V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
34-304
34
Table 34-395. Freedom IEC Open Reversing Combination Motor Controllers (A307 Manual Motor Protector + CE55 IEC 45 mm Reversing Contactor)
Table 34-396. AC and DC Coil Suffixes
AC Coils
DC Coils
FLA
Adjustment
Range
11.0 – 16.0
14.0 – 20.0
17.0 – 22.0
Coil Volts and Hertz
120/60 or 110/50
240/60 or 220/50
480/60 or 440/50
600/60 or 550/50
208/60
277/60
380 – 415/50
24/60, 24/50
120V DC
0.11 – 0.16
0.14 – 0.20
0.18 – 0.25
0.22 – 0.32
0.28 – 0.40
0.35 – 0.50
0.45 – 0.63
0.55 – 0.8
0.7 – 1.0
0.9 – 1.25
1.1 – 1.6
1.4 – 2.0
1.8 – 2.5
2.2 – 3.2
2.8 – 4.0
3.5 – 5.0
4.5 – 6.3
5.5 – 8.0
7.0 – 10.0
9.0 – 12.5
12V DC
24V DC
48V DC
AE357 — Freedom IEC Open Reversing
Combination Motor Controller
Select motor controller by motor Full Load Amperes. Horsepower ratings are for reference only.
Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-396 below.
Mounting plate included.
Add -DIN Modification Code for DIN Rail mounting of contactors with MMP and Wiring Connector Link.
IEC Contactors & Starters
Freedom MMPs & Manual and Combination Motor Controllers
Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC Combination Motor Controllers
Single-Phase
hp Ratings
115V
1
1-1/2
2
1/10
1/8
1/6
1/4
1/3
1/2
1/2
230V
1
1-1/2
2
3
3
3
1/10
1/8
1/6
1/4
1/3
1/2
3/4
Code Suffix
A
B
C
D
E
H
L
T
A1
R1
T1
W1
Three-Phase
hp Ratings
200V
1
1-1/2
2
3
3
5
5
7-1/2
1/4
1/3
1/2
3/4
3/4
230V
1
1
1-1/2
2
3
3
5
7-1/2
7-1/2
1/4
1/3
1/2
1/2
3/4
For use as CMCs in Group Installation
or UL 508 Type F applications.
When Ordering Specify —
Notes —
460V
10
15
15
For more information visit: www.eaton.com
Select required assembled motor
controller by Catalog Number from
Table 34-395 and replace underscore
(_) in the Catalog Number with the
proper Magnetic Coil Code Suffix
Letter from Table 34-396.
All Non-reversing and Reversing
motor controllers are selected based
on the overload current range
required for a given motor. This cur-
rent range is determined from the
motor Full Load Ampere rating and
Motor Service Factor usually found
on the motor nameplate.
Each Combination Motor Controller
Includes: (1) C320FMC11 Front
Mount Auxiliary Contact 1NO/1NC.
The CE55***C* signifies a black
base, A1 & A2 coil terminals at the
bottom and black printing on the
label.
For information on the usage of
Line Side Adapters, see Table 34-
403, Page 34-307.
1
1-1/2
1-1/2
2
3
5
5
7-1/2
7-1/2
1/4
1/2
3/4
3/4
The auxiliary contact is desig-
nated by the S in the following
Catalog Number example:
AE357ANS3A.
575V
10
10
15
20
20
1
1-1/2
1-1/2
2
3
3
5
5
1/4
1/2
1/2
3/4
Manual
Motor
Protector
A307AN
A307BN
A307CN
A307DN
A307EN
A307FN
A307GN
A307HN
A307JN
A307KN
A307LN
A307MN
A307NN
A307PN
A307RN
A307SN
A307TN
A307UN
A307VN
A307WN
A307XN
A307YN
A307ZN
IEC Reversing
Contactor
CE55ANSC3_B
CE55ANSC3_B
CE55ANSC3_B
CE55ANSC3_B
CE55ANSC3_B
CE55ANSC3_B
CE55ANSC3_B
CE55ANSC3_B
CE55ANSC3_B
CE55ANSC3_B
CE55ANSC3_B
CE55ANSC3_B
CE55ANSC3_B
CE55ANSC3_B
CE55ANSC3_B
CE55ANSC3_B
CE55BNSC3_B
CE55BNSC3_B
CE55CNSC3_B
CE55CNSC3_B
CE55DNSC3_B
CE55ENSC3_B
CE55FNSC3_B
Instructional Leaflets
See Page 34-300 for Listing.
Note: For more information on Manual
Motor Protectors and Wiring Connector
Links refer to Pages 34-294 – 34-299. For
Freedom Contactors refer to Pages 34-261 –
34-289.
Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-307
Dimensions . . . . . . . . . . . . . . . . . . . . . . Page 34-308
Discount Symbol . . . . . . . . . . . . . . . . . 1CD7
For motors with service factors less
than 1.15, multiply the motor FLA by
.92 to select the appropriate motor
controller. Example: For a motor
having FLA of 6.4A and a service
factor of 1.0 (6.4A x .92 = 5.88A)
select Catalog Number
AE357TNS3_.
For motors with service factor of
1.15 or greater, use motor name-
plate Full Load Amperes to select
the appropriate motor controller.
Example: For motor having FLA of
6.4A and service factor of 1.15,
select Catalog Number
AE357UNS3_.
Catalog
Number
AE357ANS3_
AE357BNS3_
AE357CNS3_
AE357DNS3_
AE357ENS3_
AE357FNS3_
AE357GNS3_
AE357HNS3_
AE357JNS3_
AE357KNS3_
AE357LNS3_
AE357MNS3_
AE357NNS3_
AE357PNS3_
AE357RNS3_
AE357SNS3_
AE357TNS3_
AE357UNS3_
AE357VNS3_
AE357WNS3_
AE357XNS3_
AE357YNS3_
AE357ZNS3_
Price
U.S. $
AC Coil
CA08102001E
March 2009
DC Coil

Related parts for XTOB001CC1