XTOB001CC1 EATON CUTLER HAMMER, XTOB001CC1 Datasheet - Page 48

Overload Relay

XTOB001CC1

Manufacturer Part Number
XTOB001CC1
Description
Overload Relay
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTOB001CC1

Overload Adjustment Current Min
0.6A
Overload Adjustment Current Max
1A
Coil Voltage Dc Max
220V
Contactor Direction
Non Reversing
Coil Voltage Vdc Nom
220V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
34
34-48
Table 34-73. XTCC Contactors for Three-Phase Capacitors
Notes:
Figure 34-36. Wiring Diagram
Three-Phase Capacitors, 50 – 60 Hz
Open kVar Ratings
230V
11
15
20
25
Weld-resistant for capacitors with inrush
current peaks up to 180 x I N .
In the case of group compensation multi-
stage capacitor banks are connected to the
mains, as required. In the process, transient
currents of up to 180 x I e can flow between
the capacitors. The capacitors are pre-
charged via the early-make auxiliary contacts
and the fitted wire resistors, thereby reducing
the inrush current. The main contacts then
close after a time lag and carry the
uninterrupted current. The contactors for
capacitors are weld-resistant with inrush
current peaks up to 180 x 1 I e due to their
special contacts. For switching reactive-
power compensation equipment with
chokes, observe design notes.
With series resistors, without quick-discharge resistor.
Underscore (_) indicates magnet coil suffix required, see Table 34-74.
Contact Eaton for availability.
IEC Contactors & Starters
XT IEC Power Control
Contactors and Starters
400V
20
25
33.3
50
A1
A2
R11
525V
25
33.3
40
65
L1 L2 L3
1
2
R11
C1
3
4
5
6
690V
33.3
40
55
85
R11
Contact
Sequence
A1
A2
A1
A2
Table 34-74. Magnet Coil Suffix
Coil Voltage
110V 50 Hz, 120V 60 Hz
220V 50 Hz, 240V 60 Hz
230V 50 Hz, 240V 60 Hz
400V 50 Hz, 440V 60 Hz
24V 50/60 Hz
For switching of power factor connection
with reactors please observe engineering
notes, Table 34-75. Use of the contactors
XTCE without series resistor for centralized
power factor correction — when using
contactors for group compensation, a
minimum inductance of approximately 6 μH
per capacitor must be available to limit the
high inrush current peaks. This corresponds
to an air-cored coil with 5 windings and a coil
diameter of approximately 140 mm diameter.
The conductor cross-section must be
selected according to the rated current
per phase.
1
2
For more information visit: www.eaton.com
1
2
3
4
3
4
5
6
5
6
13
14
13
14
21
22
Catalog
Number
XTCC020C11_
XTCC025C11_
XTCC033D10_
XTCC050D10_
Suffix
Code
A
B
F
N
T
Price
U.S. $
Table 34-75. Engineering Notes for XTCC and
XTCE Contactors for Power Factor Correction
Individual Compensation, Open Version
Group Compensation, with Reactor, Open Version
Group Compensation, without Reactor,
Open Version
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7
Catalog
Number
XTCE007B
XTCE009B
XTCE012B
XTCE015B
XTCE018C
XTCE025C
XTCE032C
XTCE040D
XTCE050D
XTCE065D
XTCE080F
XTCE095F
XTCE115G
XTCE150G
XTCE185L
XTCE300M
XTCE580N
XTCE007B
XTCE009B
XTCE012B
XTCE015B
XTCE018C
XTCE025C
XTCE032C
XTCE040D
XTCE050D
XTCE065D
XTCE080F
XTCE095F
XTCE115G
XTCE150G
XTCE185L
XTCE225L
XTCE250L
XTCE300M
XTCE400M
XTCE500M
XTCC020C
XTCC025C
XTCC033D
XTCC050D
XTCR185L
XTCE300M
XTCE580N
Switching Duty in kVar
230V
115
175
100
110
130
160
220
145
11
11.5
12.5
16
18
24
28
87
10
13
16
19
30
34
44
50
80
11
15
20
25
66
85
1.5
2
2.5
2.5
6.5
7
7.5
4
5
5.5
5.5
7.5
9
400V
420V
440V
150
200
300
150
175
190
225
280
390
115
150
250
12
13.5
14.5
20.5
22
23.5
30.5
34
46
53
10
10
16
18
20
25
30
36
58
66
80
97
20
25
33.3
50
3
4
4.5
4.5
7
8
525V
190
265
400
100
115
200
230
260
290
370
500
145
195
333
14.5
16
17
24.5
26
28
36.5
41
54.5
63.5
10
12
12
20
23
24
30
36
43
68
79
25
33.3
40
65
3.5
4.5
5.5
5.5
7.5
CA08102001E
March 2009
690V
150
200
300
104
125
152
260
300
340
390
480
680
115
150
250
19
21
22.5
32
34.5
37
48
54
72
83.5
12
14
16
16
28
30
32
40
48
57
90
33.3
40
55
85
5
6
7
7

Related parts for XTOB001CC1