XTOB001CC1 EATON CUTLER HAMMER, XTOB001CC1 Datasheet - Page 200

Overload Relay

XTOB001CC1

Manufacturer Part Number
XTOB001CC1
Description
Overload Relay
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTOB001CC1

Overload Adjustment Current Min
0.6A
Overload Adjustment Current Max
1A
Coil Voltage Dc Max
220V
Contactor Direction
Non Reversing
Coil Voltage Vdc Nom
220V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
34-200
34
Table 34-232. S — System Voltage, Selector Switches, Suppressor,
Incomplete Sequence Protection, Single-Phase Jumper, Surge
Capacitor, Speed Potentiometer
Modification Catalog
System
Voltage
Selection
Selector
Switches
Suppressor
Sequence
Timer
Sequence
Protection
Single
Phase
When using 3-position selector switch with magnetic lighting
contactor, mod C20 must also be used (ECL04, ECL13, ECL15).
IEC Contactors & Starters
XT IEC Power Control
Contactors and Starters — Enclosed Control
Number
Suffix
S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
S15
S16
S17
S18
S21
S41
S42
S43
S40
S24
S26
S27
S29
S30
S31
Description
System Voltage Selection for Internal
Components
/H1
/H2
/H3
/H4
/H5
/H6
/H7
/H8
/H9
/H10
/H11
/H12
/H13
System Voltage Selection — Specify on
Order
HAND/OFF/AUTO
HAND/AUTO
HAND/OFF/AUTO Selector Switch with 1
Red RUN Pilot Light
RUN/OFF/AUTO
AUTO/OFF/TEST
AUTO/OFF/TEST Selector Switch with 1
Red RUN Pilot Light
AUTO/OFF/TEST Selector Switch with 1
Red RUN Pilot Light and 1 Green Pilot
Light
OFF/AUTO
START/STOP
OFF/ON
HIGH/LOW
FAST/OFF/SLOW
SLOW/FAST
FORWARD/REVERSE
HIGH/OFF/LOW
HIGH/LOW/OFF/AUTO
HAND/OFF/AUTO Spring Return from Left
OPEN/OFF/CLOSE
FORWARD/OFF/REVERSE
FAST/OFF/SLOW/AUTO
Selector Switch — Order by Description
Transient Suppressor Mounted
on Magnet Coil
Sequence Timer (Pump Panels)
Incomplete Sequence Protection
Convert Contactor or Starter from Three-
Phase to Single-Phase — Install Jumper
Single-Phase Rev. 120V
Single-Phase Rev. 240V
1500V 60 Hz
208V 60 Hz
240V 60 Hz
277V 60 Hz, 1-Ph
480V 60 Hz
600V 60 Hz
796V 60 Hz
220V 50 Hz
380V 50 Hz
415V 50 Hz
550V 50 Hz
660V 50 Hz
380V 60 Hz
For more information visit: www.eaton.com
Adder
U.S. $
Table 34-233. T — Timers, Time Delay Relays, Terminal Blocks,
Terminal Points, Ring Lug Connections
Table 34-234. U — Undervoltage Relay, Time Delay Undervoltage Relay
Modification
Undervoltage
Relays
Time Delay
Undervoltage
Relays
Under- and
Overvoltage
Relay
Modification
Timers
Time Delay
Relays
Terminal
Blocks
Terminal
Points
Ring Lug
Connections
Catalog
Number
Suffix
U1
U2
U4
U5
U7
Catalog
Number
Suffix
T1
T2
T3
T4
T5
T25
T6
T7
T8
T9
T10
T24
T11
T12
T13
T14
T15
T21
T22
T17
Description
Undervoltage Relay, Non-adjustable
Undervoltage Relay, Adjustable
Time Delay Undervoltage Relay,
Non-adjustable
Time Delay Undervoltage Relay,
Adjustable
Under- and Overvoltage Relay
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
Description
Pneumatic Timer Installed on Contac-
tor, Unwired, 30 Sec. Max.
Pneumatic Timer Installed on Contac-
tor, Unwired, 180 Sec. Max.
Pneumatic Timer Mounted in Enclo-
sure, Unwired, 180 Sec. Max.
Solid-State ON Delay Timer
(1 – 30 Sec.)
Solid-State ON Delay Timer
(30 – 300 Sec.)
Timer — Order by Description
Time Delay Relay, 3 Minutes Maximum,
Unwired, ON DELAY
Time Delay Relay, 3 Minutes Maximum,
Unwired, OFF DELAY
Time Delay Low Voltage Release Relay
With 1 Single Circuit Terminal Block,
Unwired
With 2 Single Circuit Terminal Block,
Unwired
Power Terminal Block for DeviceNet
Overload
With 6 Terminal Points, Unwired
With 12 Terminal Points, Unwired
With 18 Terminal Points, Unwired
Terminal Point per Customer
Specification, Unwired (Price Each)
Terminal Point per Customer
Specification, Wired (Price Each)
3 Terminals Mounted Between
Contactor and Overload for Power
Factor Capacitors — Sizes 0 – 2
3 Terminals Mounted Between
Contactor and Overload for Power
Factor Capacitors — Sizes 3 – 4
Ring Lug Connections on Control Wires
CA08102001E
March 2009
Adder
U.S. $
Adder
U.S. $