XTOB001CC1 EATON CUTLER HAMMER, XTOB001CC1 Datasheet - Page 279

Overload Relay

XTOB001CC1

Manufacturer Part Number
XTOB001CC1
Description
Overload Relay
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTOB001CC1

Overload Adjustment Current Min
0.6A
Overload Adjustment Current Max
1A
Coil Voltage Dc Max
220V
Contactor Direction
Non Reversing
Coil Voltage Vdc Nom
220V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
March 2009
DC Magnet Coils
When Ordering Specify
Conversion Kit for Field Assembly
Factory Installed DC Coil
Application
Table 34-353. Product Selection DC Magnet Coils
Non-reversing — Kit includes NCI Side Mounted Auxiliary Contact
Reversing
CA08102001E
Contactor or
Starter Size
NEMA
00 and 0
CN35 – A, B, D
D15 Relays
00 and 0
CN35 – A, B, D
D15 Relays
1 and 2
CN35 – G
3
CN35 – K
4 and 5
CN35 – N, S
00 and 0
CN35 – A, B, D
D15 Relays
1 and 2
CN35 – G
These kits are supplied with a NO/NCI side mounted auxiliary contact in place of the NCI contact.
Kit does not include mechanical interlock or crossover wiring. Two NO/NCI top mounted auxiliary contacts are supplied for electrical interlocking.
Factory installed DC coils on NEMA contactors and starters include a NO/NC top mounted auxiliary contact on each contactor for electrical interlock-
ing. On IEC contactors and starters, a NC top mounted auxiliary contact is supplied on each contactor for electrical interlocking.
Available factory assembled only.
Two required per reversing assembly.
Catalog Number
For factory installed DC magnet coil
on AC contactors or non-combina-
tion starters (open type only), sub-
stitute the Code Suffix from table
below for the magnet coil identifier
in the device Catalog Number.
EXAMPLE: For Size 0 AC contactor
with a 24V DC coil, change
CN15BN3AC to CN15BN3T1C.
Connect for separate control
Not for use with cover control
switch operators
Use twin break, heavy-duty pilot
devices
Designed for +10%, -20% rated volt-
age, continuous duty operation
IEC
A – F
A – F
G – K
L – N
P – S
A – F
G – K
Conversion Data
Volts
120
120
120
120
120
240
120
120
12
24
48
12
24
48
12
24
48
12
24
48
24
48
12
24
48
12
24
48
Magnet Coil
Coil
Number
9-2988-11
9-2988-12
9-2988-13
9-2988-14
9-2988-11
9-2988-12
9-2988-13
9-2988-14
9-2990-1
9-2990-2
9-2990-3
9-2990-4
9-3002-1
9-3002-2
9-3002-3
9-3002-4
9-2026-4
9-2026-3
9-2026-2
9-2026-1
9-2988-1
9-2988-2
9-2988-3
9-2988-4
9-2990-1
9-2990-2
9-2990-3
9-2990-4
Amps
P.U./Seal
15.4/.42
24/.40
12/.20
18/.22
15.4/.42
6.4/.28
3.2/.14
1.6/.07
6.4/.28
3.2/.14
1.6/.07
7.7/.21
3.9/.11
1.5/.041
6.1/.097
2.5/.038
9/.11
3.3/.05
1.7/.02
6.4/.28
3.2/.14
1.6/.07
7.7/.21
3.9/.11
1.5/.041
.64/.028
.64/.028
.64/.028
Non-reversing Kit Consists of:
Operation
These DC coil kits have separate pick-
up and seal windings. A special (side
mounted) early-break NCI auxiliary
contact is used to either disconnect the
pick-up winding or insert the seal
winding in series with the pick-up
winding, depending on the frame size
of the contactor. DC coil kits come in
two styles, a suffix 1 and a suffix 4. The
1 suffix contains only the special (side
mounted) early break NCI auxiliary
contact. The 4 suffix contains a NO
contact in the same package as the
special (side mounted) early-break NCI
auxiliary contact.
For more information visit: www.eaton.com
1 Encapsulated DC magnet coil
1 NCI or NO/NCI side mounted
auxiliary contact
Note: These kits are supplied with a NO/
NCI side mounted auxiliary contact in
place of the NCI contact.
2 Blue colored connection wires
1 Instruction publication
IEC Contactors & Starters
Freedom
Accessories
Watts
P.U./Seal
185/4.98
185/4.96
185/5.04
185/4.87
293/4.84
288/4.75
295/4.67
298/4.57
400/5.3
400/5.2
450/5.4
440/4.9
185/4.98
185/4.96
185/5.04
185/4.87
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
NCI
Interlock
Number
C320KGD1
C320KGD1
C320KGD1
C320KGD1
C320KGD2
C320KGD2
C320KGD2
C320KGD2
C320KGD5
C320KGD5
C320KGD5
C320KGD5
C320KGD3
C320KGD3
C320KGD3
C320KGD3
C320KGD3
C320KGD3
C320KGD3
C320KGD3
C320KGD1
C320KGD1
C320KGD1
C320KGD1
C320KGD3
C320KGD3
C320KGD3
C320KGD3
Complete Conversion Kit
Catalog
Number
C335KD3R1
C335KD3T1
C335KD3W1
C335KD3A1
C335KD3R4
C335KD3T4
C335KD3W4
C335KD3A4
C335KD4R4
C335KD4T4
C335KD4W4
C335KD4A4
C335KD5R1
C335KD5T1
C335KD5W1
C335KD5A1
C335KA3T1
C335KA3W1
C335KA3A1
C335KA3B1
C335KD3R1
C335KD3T1
C335KD3W1
C335KD3A1
Note: For NEMA Sizes 00 and 0 and IEC
Sizes A – F, contactors may utilize either
suffix 1 or 4 DC coil kits; starters may utilize
suffix 4 DC coil kits only. For NEMA Sizes 1
and 2 and IEC Sizes G – K, both contactors
and starters may utilize a suffix 4 DC coil kit
only.
On the above sizes only, when the
special auxiliary package is mounted
on the side of a contactor or starter,
no standard auxiliary contact may be
mounted on the same side.
Note: For NEMA Sizes 3 – 5 and IEC Sizes
L – S, the special coil NCI clearing contact is
an add-on auxiliary (must mount on a base
mount auxiliary contact; normally a 1NO).
This arrangement will normally account for
two of the three contact positions on the
side of each contactor or starter.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
Price
U.S $
Ship Wt.
Lbs. (kg)
1.0 (.5)
1.0 (.5)
1.0 (.5)
2.0 (.9)
2.5 (1.1)
1.0 (0.9)
Factory Installed
Code
Suffix
R1
T1
W1
A1
R4
T4
W4
A4
R4
T4
W4
A4
R1
T1
W1
A1
T1B
W1B
A1B
B1B
R1
T1
W1
A1
R1
T1
W1
A1
Adder
U.S $
34-279
34

Related parts for XTOB001CC1