PAXS0010 Red Lion Controls, PAXS0010 Datasheet - Page 13

Strain Gauge Meter

PAXS0010

Manufacturer Part Number
PAXS0010
Description
Strain Gauge Meter
Manufacturer
Red Lion Controls
Type
Strain Gager
Datasheets

Specifications of PAXS0010

No. Of Digits / Alpha
5
Meter Function
DC Millivoltmeter
Meter Range
± 24mV To ± 240mV
Digit Height
14.2mm
Power Consumption
11W
Operating Temperature Range
0°C To +50°C
Supply Voltage Dc, Min
11V
Accuracy
0.07% of Reading +4 µV
Brand/series
PAX
Character Height
0.56 in.
Connection Type
2-Wire (Single-Ended), 4-Wire Bridge (Differential)
Cut Out, Panel
1⁄8 DIN
Dimensions
4.2" L × 3.8" W × 1.95" H
Display Digit Height
0.56 "
Display Resolution
1 μV/10 μV
Display Type
LED
Function
Strain Gage
Input Type
Strain Gauge/Bridge Input
Number Of Digits
5
Primary Type
Electronic
Range, Measurement
±24/±240 mvDC
Special Features
Programmable Function Keys
Temperature Range
0 to +50 °C
Temperature, Storage
–40 to +60 °C
Termination
Cage Clamp
Voltage, Input
11-36 VDV, 24 VAC
Lead Free Status / RoHS Status
na
3.3 USER INPUT WIRING
Inputs, then skip this section. Only the appropriate User Input terminal has to be wired.
Sinking Logic
Terminal 8-10:
Terminal 7:
Sinking Logic
Terminals 9-11
Terminal 8
3.4 SETPOINT (ALARMS) WIRING
3.5 SERIAL COMMUNICATION WIRING
3.6 ANALOG OUTPUT WIRING
4.0 R
PAXH ONLY
Before connecting the wires, the User Input Logic Jumper should be verified for proper position. If not using User
In this logic, the user inputs of the
meter are internally pulled up to +5 V
with 22 K resistance. The input is active
when it is pulled low (<0 .9 V).
In this logic, the user inputs of the
meter are internally pulled up to +5 V
with 22 K resistance. The input is
active when it is pulled low (<0 .9 V).
}
}
* Display Readout Legends may be locked out in Factory Settings.
** Factory setting for the F1, F2, and RST keys is NO mode.
Connect external
switching device between
appropriate User Input
terminal and User Comm.
KEY
DSP
PAR
F1
F2
RST
Connect external switching device between
appropriate User Input terminal and User Comm.
EVIEWING THE
"
!
DISPLAY MODE OPERATION
Index display through max/min/total/input readouts
Access parameter list
Function key 1; hold for 3 seconds for Second Function 1**
Function key 2; hold for 3 seconds for Second Function 2**
Reset (Function key)**
F
RONT
See appropriate plug-in card bulletin for details.
Sourcing Logic
Terminal 8-10: + VDC thru external switching device
Terminal 7: -VDC thru external switching device
13
Sourcing Logic
Terminals 9-11:
Terminal 8:
In this logic, the user inputs of the meter are
internally pulled down to 0 V with 22 K
resistance. The input is active when a voltage
greater than 3.6 VDC is applied.
+ VDC through external switching device
-VDC through external switching device
In this logic, the user inputs of the meter are
internally pulled down with 22 K resistance.
The input is active when a voltage greater
than 3.6 VDC is applied.
PROGRAMMING MODE OPERATION
Quit programming and return to display mode
Store selected parameter and index to next parameter
Increment selected parameter value
Decrement selected parameter value
Hold with F1
B
UTTONS AND
"
, F2
!
to scroll value by x1000
D
ISPLAY

Related parts for PAXS0010