PAXS0010 Red Lion Controls, PAXS0010 Datasheet - Page 7

Strain Gauge Meter

PAXS0010

Manufacturer Part Number
PAXS0010
Description
Strain Gauge Meter
Manufacturer
Red Lion Controls
Type
Strain Gager
Datasheets

Specifications of PAXS0010

No. Of Digits / Alpha
5
Meter Function
DC Millivoltmeter
Meter Range
± 24mV To ± 240mV
Digit Height
14.2mm
Power Consumption
11W
Operating Temperature Range
0°C To +50°C
Supply Voltage Dc, Min
11V
Accuracy
0.07% of Reading +4 µV
Brand/series
PAX
Character Height
0.56 in.
Connection Type
2-Wire (Single-Ended), 4-Wire Bridge (Differential)
Cut Out, Panel
1⁄8 DIN
Dimensions
4.2" L × 3.8" W × 1.95" H
Display Digit Height
0.56 "
Display Resolution
1 μV/10 μV
Display Type
LED
Function
Strain Gage
Input Type
Strain Gauge/Bridge Input
Number Of Digits
5
Primary Type
Electronic
Range, Measurement
±24/±240 mvDC
Special Features
Programmable Function Keys
Temperature Range
0 to +50 °C
Temperature, Storage
–40 to +60 °C
Termination
Cage Clamp
Voltage, Input
11-36 VDV, 24 VAC
Lead Free Status / RoHS Status
na
Adding Option Cards
in cards. The details for each plug-in card can be reviewed in the specification
section below. Only one card from each function type can be installed at one time.
The function types include Setpoint Alarms (PAXCDS), Communications
(PAXCDC), and Analog Output (PAXCDL). The plug-in cards can be installed
initially or at a later date.
PAXH Isolation Specifications For All Option Cards
Isolation To Sensor Commons: 1400 Vrms for 1 min.
Isolation to User Input Commons: 500 Vrms for 1 min.
COMMUNICATION CARDS (PAXCDC)
series. Only one of these cards can be installed at a time. When programming
the unit via RLCPro, a Windows
must be used.
SERIAL COMMUNICATIONS CARD
DEVICENET™ CARD
MODBUS CARD
PROFIBUS-DP CARD
PROGRAMMING SOFTWARE
configuration of the PAX
menu commands, that make it easy to program the meter. The meter’s program
can then be saved in a PC file for future use. A PAX
required to program the meter using the software.
O
The PAX and MPAX series meters can be fitted with up to three optional plug-
Working Voltage: 125 V
Working Voltage 50 V
A variety of communication protocols are available for the PAX and MPAX
Type: RS485 or RS232
Isolation To Sensor & User Input Commons: 500 Vrms for 1 min.
Data: 7/8 bits
Baud: 300 to 19,200
Parity: no, odd or even
Bus Address: Selectable 0 to 99, Max. 32 meters per line (RS485)
Transmit Delay: Selectable for 2 to 50 msec or 50 to 100 msec (RS485)
Compatibility: Group 2 Server Only, not UCMM capable
Baud Rates: 125 Kbaud, 250 Kbaud, and 500 Kbaud
Bus Interface: Phillips 82C250 or equivalent with MIS wiring protection per
Node Isolation: Bus powered, isolated node
Host Isolation: 500 Vrms for 1 minute (50 V working) between DeviceNet™
Type: RS485; RTU and ASCII MODBUS modes
Isolation To Sensor & User Input Commons: 500 Vrms for 1 minute.
Baud Rates: 300 to 38400.
Data: 7/8 bits
Parity: No, Odd, or Even
Addresses: 1 to 247.
Transmit Delay: Programmable; See Transmit Delay explanation.
Fieldbus Type: Profibus-DP as per EN 50170, implemented with Siemens
Conformance: PNO Certified Profibus-DP Slave Device
Baud Rates: Automatic baud rate detection in the range 9.6 Kbaud to 12 Mbaud
Station Address: 0 to 126, set by the master over the network. Address stored
Connection: 9-pin Female D-Sub connector
Network Isolation: 500 Vrms for 1 minute (50 V working) between Profibus
The Crimson
Working Voltage: 50 V. Not Isolated from all other commons.
DeviceNet™ Volume I Section 10.2.2.
and meter input common.
Working Voltage: 50 V. Not isolated from all other commons.
SPC3 ASIC
in non-volatile memory.
network and sensor and user input commons. Not isolated from all other
commons.
PTIONAL
PAXCDC10 - RS485 Serial
PAXCDC20 - RS232 Serial
PAXCDC30 - DeviceNet
WARNING: Disconnect all power to the unit before
installing Plug-in cards.
®
software is a Windows
®
meter from a PC. Crimson offers standard drop-down
®
P
based program, the RS232 or RS485 Cards
LUG
PAXCDC40 - Modbus
PAXCDC50 - Profibus-DP
®
based program that allows
-
IN
®
serial plug-in card is
O
UTPUT
7
SETPOINT CARDS (PAXCDS)
cards. Only one of these cards can be installed at a time. (Logic state of the
outputs can be reversed in the programming.) These plug-in cards include:
DUAL RELAY CARD
QUAD RELAY CARD
QUAD SINKING OPEN COLLECTOR CARD
QUAD SOURCING OPEN COLLECTOR CARD
ALL FOUR SETPOINT CARDS
LINEAR DC OUTPUT (PAXCDL)
from the analog output plug-in card. The programmable output low and high
scaling can be based on various display values. Reverse slope output is possible
by reversing the scaling point positions.
ANALOG OUTPUT CARD
The PAX and MPAX series has 4 available setpoint alarm output plug-in
Type: Two FORM-C relays
Isolation To Sensor & User Input Commons: 2000 Vrms for 1 min.
Contact Rating:
Life Expectancy: 100 K cycles min. at full load rating. External RC snubber
Type: Four FORM-A relays
Isolation To Sensor & User Input Commons: 2300 Vrms for 1 min.
Contact Rating:
Life Expectancy: 100K cycles min. at full load rating. External RC snubber
Type: Four isolated sinking NPN transistors.
Isolation To Sensor & User Input Commons: 500 Vrms for 1 min.
Rating: 100 mA max @ V
Type: Four isolated sourcing PNP transistors.
Isolation To Sensor & User Input Commons: 500 Vrms for 1 min.
Rating: Internal supply: 24 VDC ± 10% , 30 mA max. total
Response Time: 200 msec. max. to within 99% of final readout value (digital
Either a 0(4)-20 mA or 0-10 V retransmitted linear DC output is available
Types: 0 to 20 mA, 4 to 20 mA or 0 to 10 VDC
Isolation To Sensor & User Input Commons: 500 Vrms for 1 min.
Accuracy: 0.17% of FS (18 to 28°C); 0.4% of FS (0 to 50°C)
Resolution: 1/3500
Compliance: 10 VDC: 10 K load min., 20 mA: 500
Powered: Self-powered
Update time: 200 msec. max. to within 99% of final output value (digital
C
PAXCDS10 - Dual Relay, FORM-C, Normally open & closed
PAXCDS20 - Quad Relay, FORM-A, Normally open only
PAXCDS30 - Isolated quad sinking NPN open collector
PAXCDS40 - Isolated quad sourcing PNP open collector
Working Voltage: 240 Vrms
One Relay Energized: 5 amps @ 120/240 VAC or 28 VDC (resistive load),
Total current with both relays energized not to exceed 5 amps
extends relay life for operation with inductive loads
Working Voltage: 250 Vrms
One Relay Energized: 3 amps @ 240 VAC or 30 VDC (resistive load), 1/10
Total current with all four relays energized not to exceed 4 amps
extends relay life for operation with inductive loads
Working Voltage: 50 V.
Working Voltage: 50 V.
filter and internal zero correction disabled)
PAXCDL10 - Retransmitted Analog Output Card
Working Voltage: 50 V.
filter and internal zero correction disabled)
1/8 HP @120 VAC, inductive load
HP @120 VAC, inductive load
External supply: 30 VDC max., 100 mA max. each output
700 msec. max. (digital filter disabled, internal zero correction enabled)
700 msec. max. (digital filter disabled, internal zero correction enabled)
ARDS
SAT
Not Isolated from all other commons.
Not Isolated from all other commons.
Not Isolated from all other commons.
= 0.7 V max. V
MAX
= 30 V
load max.

Related parts for PAXS0010