CJ1W-PNT21 Omron, CJ1W-PNT21 Datasheet - Page 82

no-image

CJ1W-PNT21

Manufacturer Part Number
CJ1W-PNT21
Description
CJ Profinet Master
Manufacturer
Omron
Datasheet

Specifications of CJ1W-PNT21

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Allocated CIO Area Words
Bit
04
05
06
07
08
09
10~12
13
14~15
Name
Parameter transfer in
progress
Reserved by system
Local parameter stor-
age error
Local parameter load
error
Reserved
File read error
Reserved
Error
error
Reserved
log
storage
Status
OFF
ON
---
OFF
ON
OFF
ON
---
OFF
ON
---
OFF
ON
---
Unit operation
When OFF, this bit indicates that no Configuration
data transfer is in progress.
The Parameter transfer in progress indicates:
During this transfer no other transfer of data can be
started in parallel.
This bit will be set to OFF by the Unit.
When OFF, this bit indicates that the Configuration
and setup data has been transferred to the non-vola-
tile memory successfully.
The local parameter storage error flag will be ON if
an error occurred during the storage of the data
transferred from the configuration software to the
CJ1W-PNT21.nal non-volatile memory.
If the error occurred, the data in the non-volatile
memory may be corrupted and a new Configuration
must be downloaded to the Unit.
The flag will be OFF if the Configuration and setup
data has been successfully transferred from non-vol-
atile to volatile memory.
The Local parameter load error flag will be ON if the
internally stored Configuration and setup data is cor-
rupted or erased.
This bit will be set to OFF by the Unit.
The flag will be OFF if the Configuration and setup
data has been successfully transferred from
pactFlash Memory Card
The File read error flag will be ON if an error
occurred during the transfer of the Configuration and
setup data from a
the PLC CPU to the Unit’s non-volatile memory. The
error can be caused by an error in the File or an
error during transfer.
This bit will be set to OFF by the Unit.
When OFF, this bit indicates that the Error log has
been transferred to the non-volatile memory suc-
cessfully.
The Error log storage error flag will be ON if an error
occurred during an attempt to write the Error log to
internal non-volatile memory.
If the error occurred, the Error log data in the non-
volatile memory may be corrupted. Upon a restart
the Unit will reinitialise the Error log.
This bit will be set to OFF by the Unit.
Retrieval of internally stored configuration and
set-up data.
Storing of configuration and set-up data sent by
the configuration software in progress.
CompactFlash Memory Card
in the PLC CPU.
Section 5-2
Com-
69
in