MA160014 Microchip Technology, MA160014 Datasheet - Page 343

MOD PLUG-IN 44PIN PIC18LF45K22

MA160014

Manufacturer Part Number
MA160014
Description
MOD PLUG-IN 44PIN PIC18LF45K22
Manufacturer
Microchip Technology
Series
PIC® XLP™ 18Fr
Datasheet

Specifications of MA160014

Accessory Type
Plug-In Module (PIM) - PIC18LF45K10
Product
Microcontroller Modules
Data Bus Width
8 bit
Core Processor
PIC18LF45K22
Interface Type
I2C, SPI
Operating Supply Voltage
1.8 V to 5.5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
PICDEM PIC18 Explorer, DM183032
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MA160014
Manufacturer:
Microchip Technology
Quantity:
135
Part Number:
MA160014
Manufacturer:
MICROCHIP
Quantity:
12 000
23.0
The PIC18(L)F2X/4XK22 devices have a High/Low-
Voltage Detect module (HLVD). This is a programmable
circuit that sets both a device voltage trip point and the
direction of change from that point. If the device experi-
ences an excursion past the trip point in that direction, an
interrupt flag is set. If the interrupt is enabled, the pro-
gram execution branches to the interrupt vector address
and the software responds to the interrupt.
REGISTER 23-1:
 2010 Microchip Technology Inc.
bit 7
Legend:
R = Readable bit
-n = Value at POR
bit 7
bit 6
bit 5
bit 4
bit 3-0
Note 1:
VDIRMAG
R/W-0
HIGH/LOW-VOLTAGE DETECT
(HLVD)
See
Table 27-4
VDIRMAG: Voltage Direction Magnitude Select bit
1 = Event occurs when voltage equals or exceeds trip point (HLVDL<3:0>)
0 = Event occurs when voltage equals or falls below trip point (HLVDL<3:0>)
BGVST: Band Gap Reference Voltages Stable Status Flag bit
1 = Internal band gap voltage references are stable
0 = Internal band gap voltage reference is not stable
IRVST: Internal Reference Voltage Stable Flag bit
1 = Indicates that the voltage detect logic will generate the interrupt flag at the specified voltage range
0 = Indicates that the voltage detect logic will not generate the interrupt flag at the specified voltage
HLVDEN: High/Low-Voltage Detect Power Enable bit
1 = HLVD enabled
0 = HLVD disabled
HLVDL<3:0>: Voltage Detection Level bits
1111 = External analog input is used (input comes from the HLVDIN pin)
1110 = Maximum setting
.
.
.
0000 = Minimum setting
BGVST
range and the HLVD interrupt should not be enabled
R-0
HLVDCON: HIGH/LOW-VOLTAGE DETECT CONTROL REGISTER
for specifications.
W = Writable bit
‘1’ = Bit is set
IRVST
R-0
HLVDEN
R/W-0
Preliminary
(1)
U = Unimplemented bit, read as ‘0’
‘0’ = Bit is cleared
R/W-0
The
(Register
HLVD module. This allows the circuitry to be “turned
off” by the user under software control, which
minimizes the current consumption for the device.
The module’s block diagram is shown in
PIC18(L)F2X/4XK22
High/Low-Voltage
23-1) completely controls the operation of the
R/W-1
HLVDL<3:0>
x = Bit is unknown
Detect
R/W-0
DS41412D-page 343
Control
Figure
R/W-1
register
23-1.
bit 0