STM8S103F3

Manufacturer Part NumberSTM8S103F3
DescriptionAccess line, 16 MHz STM8S 8-bit MCU, up to 8 Kbytes Flash, data EEPROM
ManufacturerSTMicroelectronics
STM8S103F3 datasheet
 

Specifications of STM8S103F3

Program Memory8 Kbytes Flash; data retention 20 years at 55 °C after 10 kcyclesData Memory640 bytes true data EEPROM; endurance 300 kcycles
Ram1 KbytesAdvanced Control Timer16-bit, 4 CAPCOM channels, 3 complementary outputs, dead-time insertion and flexible synchronization
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
Page 41
42
Page 42
43
Page 43
44
Page 44
45
Page 45
46
Page 46
47
Page 47
48
Page 48
49
Page 49
50
Page 50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
Page 48/113

Download datasheet (2Mb)Embed
PrevNext
Electrical characteristics
10
Electrical characteristics
10.1
Parameter conditions
Unless otherwise specified, all voltages are referred to V
10.1.1
Minimum and maximum values
Unless otherwise specified the minimum and maximum values are guaranteed in the worst
conditions of ambient temperature, supply voltage and frequencies by tests in production on
100 % of the devices with an ambient temperature at T
the selected temperature range).
Data based on characterization results, design simulation and/or technology characteristics
are indicated in the table footnotes and are not tested in production. Based on characterization,
the minimum and maximum values refer to sample tests and represent the mean value plus
or minus three times the standard deviation (mean ± 3 Σ).
10.1.2
Typical values
Unless otherwise specified, typical data are based on T
only as design guidelines and are not tested.
Typical ADC accuracy values are determined by characterization of a batch of samples from
a standard diffusion lot over the full temperature range, where 95% of the devices have an
error less than or equal to the value indicated (mean ± 2 Σ).
10.1.3
Typical curves
Unless otherwise specified, all typical curves are given only as design guidelines and are not
tested.
10.1.4
Loading capacitor
The loading conditions used for pin parameter measurement are shown in the following figure.
48/113
STM8S103K3 STM8S103F3 STM8S103F2
SS
= 25 °C and T
A
= 25 °C, V
A
Figure 7: Pin loading conditions
STM8 PIN
50 pF
DocID15441 Rev 7
.
= T
(given by
A
Amax
= 5 V. They are given
DD