s3c2410a Samsung Semiconductor, Inc., s3c2410a Datasheet - Page 295

no-image

s3c2410a

Manufacturer Part Number
s3c2410a
Description
16/32-bit Risc Arm Microprocessor
Manufacturer
Samsung Semiconductor, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
s3c2410a-20
Manufacturer:
SAMSUNG
Quantity:
15 995
Part Number:
s3c2410a-20
Quantity:
1 238
Part Number:
s3c2410a-20
Manufacturer:
SUNMNG
Quantity:
2 000
Company:
Part Number:
s3c2410a-20
Quantity:
130
Part Number:
s3c2410a-20-Y080
Manufacturer:
SAMSUNG
Quantity:
2 890
Part Number:
s3c2410a-20-Y0R0
Manufacturer:
SAMSUNG
Quantity:
523
Part Number:
s3c2410a20-Y080
Manufacturer:
SAMSUNG/三星
Quantity:
20 000
Company:
Part Number:
s3c2410a20-YO80
Quantity:
12 000
Company:
Part Number:
s3c2410a20-YO8N
Quantity:
1 619
S3C2410A
TIMER CONTROL (TCON) REGISTER
NOTE:
Timer 4 auto reload on/off
Timer 4 manual update
Timer 4 start/stop
Timer 3 auto reload on/off
Timer 3 output inverter on/off
Timer 3 manual update
Timer 3 start/stop
Timer 2 auto reload on/off
Timer 2 output inverter on/off
Timer 2 manual update
Timer 2 start/stop
Timer 1 auto reload on/off
Timer 1 output inverter on/off
Timer 1 manual update
Timer 1 start/stop
Register
TCON
The bits have to be cleared at next writing.
TCON
0x51000008
Address
(note)
(note)
(note)
(note)
[22]
[21]
[20]
[19]
[18]
[17]
[16]
[15]
[14]
[13]
[12]
[11]
[10]
Bit
[9]
[8]
R/W
R/W
Determine auto reload on/off for Timer 4.
0 = One-shot
Determine the manual update for Timer 4.
0 = No operation
Determine start/stop for Timer 4.
0 = Stop
Determine auto reload on/off for Timer 3.
0 = One-shot
Determine output inverter on/off for Timer 3.
0 = Inverter off
Determine manual update for Timer 3.
0 = No operation
Determine start/stop for Timer 3.
0 = Stop
Determine auto reload on/off for Timer 2.
0 = One-shot
Determine output inverter on/off for Timer 2.
0 = Inverter off
Determine the manual update for Timer 2.
0 = No operation
Determine start/stop for Timer 2.
0 = Stop
Determine the auto reload on/off for Timer1.
0 = One-shot
Determine the output inverter on/off for Timer1.
0 = Inverter off
Determine the manual update for Timer 1.
0 = No operation
Determine start/stop for Timer 1.
0 = Stop
Timer control register
1 = Inverter on for TOUT3
1 = Inverter on for TOUT2
1 = Inverter on for TOUT1
1 = Interval mode (auto reload)
1 = Interval mode (auto reload)
1 = Update TCNTB2 & TCMPB2
1 = Update TCNTB1 & TCMPB1
1 = Start for Timer 2
1 = Start for Timer 1
1 = Interval mode (auto reload)
1 = Interval mode (auto reload)
1 = Update TCNTB4
1 = Update TCNTB3 & TCMPB3
1 = Start for Timer 4
1 = Start for Timer 3
Description
Description
Reset Value
0x00000000
Initial state
PWM TIMER
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
10-13