71M6542F MAXIM [Maxim Integrated Products], 71M6542F Datasheet - Page 126

no-image

71M6542F

Manufacturer Part Number
71M6542F
Description
0.1% Accuracy Over 2000:1 Current Range Energy Meter ICs
Manufacturer
MAXIM [Maxim Integrated Products]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71M6542F-IGT/F
Manufacturer:
AD
Quantity:
1 500
Part Number:
71M6542F-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6542FT-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6542FT-IGT/F
Manufacturer:
SILERGY/矽力杰
Quantity:
20 000
Part Number:
71M6542FT-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
environment for the CE by implementing the following steps:
When different CE codes are used, a different set of environment parameters need to be established.
The exact values for these parameters are listed in the Application Notes and other documentation which
accompanies the CE code.
Typically, there are thirteen 32768 Hz cycles per ADC multiplexer frame (see
This means that the product of the number of cycles per slot and the number of conversions per frame
71M6541D/F/G and 71M6542F/G Data Sheet
The parameters EQU[2:0] (I/O RAM 0x2106[7:5]), CE_E (I/O RAM 0x2106[0]), and SUM_SAMPS[12:0] are
essential to the function of the CE are stored in I/O RAM (see
details).
5.3.4 Environment
Before starting the CE using the CE_E bit (I/O RAM 0x2106[0]), the MPU has to establish the proper
must be 12 (plus one settling cycle per frame, see
FIR_LEN[1:0] = 01, I/O RAM 0x210C[2:1], (three cycles per conversion) and MUX_DIV[3:0] = 3 (3
conversions per multiplexer cycle).
Sample configurations can be copied from Demo Code provided by Teridian with the Demo Kits.
5.3.5 CE Calculations
Referring to
0x2106[7:5]).
Note:
EQU
71M6542F/G only.
2
Locate the CE code in Flash memory using CE_LCTN[5:0] (I/O RAM 0x2109[5:0])
Load the CE data into RAM
Establish the equation to be applied in EQU[2:0] (I/O RAM 0x2106[7:5])
Establish the number of samples per accumulation period in SUM_SAMPS[12:0] (I/O RAM 0x2107[4:0],
0x2108[7:0])
Establish the number of cycles per ADC multiplexer frame (MUX_DIV[3:0] (I/O RAM 0x2100[7:4]))
Apply proper values to MUXn_SEL, as well as proper selections for DIFFn_E (I/O RAM 0x210C[5:4])
and RMT_E (I/O RAM 0x2709[3]) in order to configure the analog inputs
Initialize any MPU interrupts, such as CE_BUSY, XFER_BUSY, or the power failure detection interrupt
VMAX = 600 V, IMAX = 707 A, and kH = 1 Wh/pulse are assumed as default settings
0
1
Operating CE codes with environment parameters deviating from the values specified by Teridian
leads to unpredictable results. See
VA IA – 1 element, 2W 1φ
VA*(IA-IB)/2 – 1 element, 3W 1φ
VA*IA + VB*IB – 2 element, 3W 3φ Delta
Table
78, The MPU selects the desired equation by writing the EQU[2:0] (I/O RAM
Watt & VAR Formula
(WSUM/VARSUM)
Table 78: CE EQU Equations and Element Input Mapping
Table 1
Figure 6
VA*(IA-IB)/2
VAR0SUM
and
W0SUM/
Inputs Used for Energy/Current Calculation
VA*IA
VA*IA
Table
and
5.2 I/O RAM Map – Alphabetical Order
Figure
2.
VAR1SUM
W1SUM/
VA*IB
VB*IB
7). The default configuration is
2.2.2 Input
IA-IB
I0SQ
SUM
IA
IA
Multiplexer).
I1SQ
SUM
IB
IB
for

Related parts for 71M6542F