71M6542F MAXIM [Maxim Integrated Products], 71M6542F Datasheet - Page 127

no-image

71M6542F

Manufacturer Part Number
71M6542F
Description
0.1% Accuracy Over 2000:1 Current Range Energy Meter ICs
Manufacturer
MAXIM [Maxim Integrated Products]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71M6542F-IGT/F
Manufacturer:
AD
Quantity:
1 500
Part Number:
71M6542F-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6542FT-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6542FT-IGT/F
Manufacturer:
SILERGY/矽力杰
Quantity:
20 000
Part Number:
71M6542FT-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
5.3.6 CE Front End Data (Raw Data)
Access to the raw data provided by the AFE is possible by reading addresses 0-3, 9 and 10 (decimal) shown
in
The MUX_SEL column in
example, if differential mode is enable via control bit DIFFA_E = 1 (I/O RAM 0x210C[4]), then the inputs IAP
and IAN are combined together to form a single differential input and the corresponding MUX_SEL handle is
0. Similarly, the CE RAM location column provides the CE RAM address where the sample data is stored.
Continuing with the same example, if DIFFA_E = 1, the corresponding CE RAM location where the
samples for the IAP-IAN differential input are stored is 0 and CE RAM location is not disturbed.
The IB input can be configured as a direct-connected sensor (i.e., directly connected to the 71M654x) or as a
remote sensor (i.e., using a 71M6x01 Isolated Sensor). If the remote sensor is disabled by RMT_E = 0 and
differential mode is enabled by DIFFB_E = 1 (I/O RAM 0x210C[5]), then IBP and IBN form a differential
input with a MUX_SEL handle of 2, and the corresponding samples are stored in CE RAM location 2 (CE
RAM location 3 is not disturbed). If the remote sensor enable bit RMT_E = 1 and DIFFB_E = 0 or 1, then the
MUX_SEL handle is undefined (i.e., the sensor is not connected to the 71M654x, so MUX_SEL does not
apply, see
differential IBP-IBN input are stored in CE RAM location 2 (CE RAM location 3 is not disturbed).
The voltage sensor inputs (VA and VB) do not have any associated configuration bits. VA has a MUX_SEL
handle value of 10, and its samples are stored in CE RAM location 10. VB has a MUX_SEL handle value of 9
and its samples are stored in CE RAM location 9.
5.3.7 FCE Status and Control
The CE Status Word, CESTATUS, is useful for generating early warnings to the MPU
sag warnings for phase A and B, as well as F0, the derived clock operating at the fundamental input fre-
quency. The MPU can read the CE status word at every CE_BUSY interrupt. Since the CE_BUSY inter-
rupt occurs at 2520.6 Hz, it is desirable to minimize the computation required in the interrupt handler of
the MPU.
CESTATUS provides information about the status of voltage and input AC signal frequency, which are useful
for generating an early power fail warning to initiate necessary data storage. CESTATUS represents the
CE Address
Table
0x80
79.
2.2 Analog Front End (AFE)
Notes:
* Remote interface data.
Location
ADC10
71M6542F/G only.
ADC0
ADC1
ADC2
ADC3
ADC9
ADC
CESTATUS
Name
Table 79
VB†
IBN
Pin
IAP
IAP
IBP
VA
Table 79: CE Raw Data Access Locations
shows the MUX_SEL handles for the various sensor input pins. For
0,0
10
DIFFA_E
0
0
1
2
3
9
Table 80: CESTATUS Register
Description
See description of CESTATUS bits in
MUX_SEL Handle
RMT_E, DIFFB_E
on page 12), and the samples corresponding to this remote
There are no configuration bits for ADC9, 10
0,1
1
0
2
1,0
1,1
71M6541D/F/G and 71M6542F/G Data Sheet
0,0
10
DIFFA_E
0
0
1
2
3
9
CE RAM Location
RMT_E, DIFFB_E
0,1
1
0
2
Table
1,0
2*
81.
(Table
1,1
2*
80). It contains

Related parts for 71M6542F