S9S12G96F0MLF Freescale Semiconductor, S9S12G96F0MLF Datasheet - Page 914

no-image

S9S12G96F0MLF

Manufacturer Part Number
S9S12G96F0MLF
Description
16-bit Microcontrollers - MCU 16BIT 96K FLASH
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of S9S12G96F0MLF

Rohs
yes
Core
S12
Processor Series
MC9S12G
Data Bus Width
16 bit
Maximum Clock Frequency
25 MHz
Program Memory Size
96 KB
Data Ram Size
8192 B
On-chip Adc
Yes
Operating Supply Voltage
3.13 V to 5.5 V
Operating Temperature Range
- 40 C to + 125 C
Package / Case
LQFP-48
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S9S12G96F0MLF
Manufacturer:
FREESCALE
Quantity:
5 500
Part Number:
S9S12G96F0MLF
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
S9S12G96F0MLF
Manufacturer:
FREESCALE
Quantity:
5 500
48 KByte Flash Module (S12FTMRG48K1V1)
Upon clearing CCIF to launch the Read Once command, a Read Once phrase is fetched and stored in the
FCCOB indexed register. The CCIF flag will set after the Read Once operation has completed. Valid
phrase index values for the Read Once command range from 0x0000 to 0x0007. During execution of the
Read Once command, any attempt to read addresses within P-Flash block will return invalid data.
26.4.6.5
The Program P-Flash operation will program a previously erased phrase in the P-Flash memory using an
embedded algorithm.
Upon clearing CCIF to launch the Program P-Flash command, the Memory Controller will program the
data words to the supplied global address and will then proceed to verify the data words read back as
expected. The CCIF flag will set after the Program P-Flash operation has completed.
916
8
Register
FSTAT
Program P-Flash Command
A P-Flash phrase must be in the erased state before being programmed.
Cumulative programming of bits within a Flash phrase is not allowed.
1
CCOBIX[2:0]
Table 26-40. Program P-Flash Command FCCOB Requirements
Global address [2:0] must be 000
MGSTAT1
MGSTAT0
ACCERR
Error Bit
FPVIOL
000
001
010
011
100
101
Table 26-39. Read Once Command Error Handling
MC9S12G Family Reference Manual,
Set if CCOBIX[2:0] != 001 at command launch
Set if command not available in current mode (see
Set if an invalid phrase index is supplied
None
Set if any errors have been encountered during the read
Set if any non-correctable errors have been encountered during the read
Global address [15:0] of phrase location to be programmed
0x06
CAUTION
Word 0 program value
Word 1 program value
Word 2 program value
Word 3 program value
FCCOB Parameters
Error Condition
Global address [17:16] to
identify P-Flash block
Rev.1.23
Table
26-27)
1
Freescale Semiconductor

Related parts for S9S12G96F0MLF