ATAES132-SH-ER Atmel, ATAES132-SH-ER Datasheet - Page 26

no-image

ATAES132-SH-ER

Manufacturer Part Number
ATAES132-SH-ER
Description
EEPROM AES 32Kbit EE I2C
Manufacturer
Atmel
Datasheet

Specifications of ATAES132-SH-ER

Rohs
yes
Maximum Clock Frequency
1 MHz
Operating Supply Voltage
6 V
Maximum Operating Temperature
- 40 C to + 85 C
Mounting Style
SMD/SMT
Package / Case
SOIC-8
Interface Type
I2C
Factory Pack Quantity
2300
6.3.
ReturnCode
The response packet for each ATAES132 command includes a ReturnCode to report success or failure to the host. The first
four error codes (0x01 through 0x08) may occur concurrently with other codes.
The reset command and the sleep command do not generate a ReturnCode because they do not generate a response packet.
All other ATAES132 commands generate a ReturnCode.
Table 6-16. ReturnCode field sorted by Value
If ReturnCode has any value other than 0x00, no additional data will be returned by ATAES132. If the ReturnCode is greater
than zero for any command that performs cryptographic operations, then the nonce will be invalidated.
Value
0x00
0x02
0x04
0x08
0x10
0x20
0x40
0x50
0x60
0x70
0x80
0x90
Name
Success
BoundaryError
RWConfig
BadAddr
CountErr
NonceError
MacError
ParseError
DataMatch
LockError
KeyErr
TempSenseErr
Notes
No errors
Crossed a page boundary for a write, BlockRead or EncRead. Crossed a key register
boundary for a write or EncWrite
Access to the specified user zone is not permitted due to the configuration or internal state
Attempted to write locked memory, or address is not implemented, or address is illegal for this
command
Counter limit reached, or count usage error, or restricted key error
Nonce invalid or not available. Nonce not generated with internal RNG. MacCount limit has
been reached.
Missing input MAC, or MAC compare failed
Bad opcode, bad mode, bad param, invalid length, or other encoding failure
EEPROM post-write automatic data verification failed due to data mismatch
Lock command contained bad checksum or bad MAC
Key not permitted to be used for this operation, or wrong key was used for operation. Prior
authentication has not been performed. Other authentication error or other key error.
Temperature sensor timeout error
Atmel ATAES132 Preliminary Datasheet
8760A−CRYPTO−5/11
26