M29W640GT70NA6E NUMONYX, M29W640GT70NA6E Datasheet - Page 41

no-image

M29W640GT70NA6E

Manufacturer Part Number
M29W640GT70NA6E
Description
IC FLASH 64MBIT 70NS 48TSOP
Manufacturer
NUMONYX
Series
Axcell™r
Datasheet

Specifications of M29W640GT70NA6E

Format - Memory
FLASH
Memory Type
FLASH - Nor
Memory Size
64M (8Mx8, 4Mx16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TSOP
Cell Type
NOR
Density
64Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Top
Address Bus
23/22Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
8M/4M
Supply Current
10mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W640GT70NA6E
Manufacturer:
ST
Quantity:
9 215
Part Number:
M29W640GT70NA6E
Manufacturer:
Numonyx/ST Micro
Quantity:
1 915
Part Number:
M29W640GT70NA6E
Manufacturer:
NEC
Quantity:
2 037
Part Number:
M29W640GT70NA6E
Manufacturer:
ST
0
Part Number:
M29W640GT70NA6E
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
M29W640GT70NA6E
Quantity:
2 300
5.3
5.4
5.5
5.6
Error bit (DQ5)
The error bit can be used to identify errors detected by the program/erase controller. The
error bit is set to ’1’ when a program, block erase or chip erase operation fails to write the
correct data to the memory. If the error bit is set a Read/Reset command must be issued
before other commands are issued. The error bit is output on DQ5 when the status register
is read.
Note that the Program command cannot change a bit set to ’0’ back to ’1’ and attempting to
do so will set DQ5 to ‘1’. A bus read operation to that address will show the bit is still ‘0’. One
of the erase commands must be used to set all the bits in a block or in the whole memory
from ’0’ to ’1’.
Erase timer bit (DQ3)
The erase timer bit can be used to identify the start of program/erase controller operation
during a Block Erase command. Once the program/erase controller starts erasing the erase
timer bit is set to ’1’. Before the program/erase controller starts the erase timer bit is set to ’0’
and additional blocks to be erased may be written to the command interface. The erase
timer bit is output on DQ3 when the status register is read.
Alternative toggle bit (DQ2)
The alternative toggle bit can be used to monitor the program/erase controller during erase
operations. The alternative toggle bit is output on DQ2 when the status register is read.
During chip erase and block erase operations the toggle bit changes from ’0’ to ’1’ to ’0’,
etc., with successive bus read operations from addresses within the blocks being erased. A
protected block is treated the same as a block not being erased. Once the operation
completes the memory returns to read mode.
During erase suspend the alternative toggle bit changes from ’0’ to ’1’ to ’0’, etc. with
successive bus read operations from addresses within the blocks being erased. Bus read
operations to addresses within blocks not being erased will output the memory cell data as if
in read mode.
After an erase operation that causes the error bit to be set the alternative toggle bit can be
used to identify which block or blocks have caused the error. The alternative toggle bit
changes from ’0’ to ’1’ to ’0’, etc. with successive bus read operations from addresses within
blocks that have not erased correctly. The alternative toggle bit does not change if the
addressed block has erased correctly.
Figure 20: Toggle/alternative toggle bit polling AC waveforms (8-bit mode)
description of the data polling operation and timings.
Write to buffer and program abort bit (DQ1)
The write to buffer and program abort bit, DQ1, is set to ‘1’ when a write to buffer and
program operation aborts. Otherwise, DQ1 bit is set to ‘0’. The Write to Buffer and Program
Abort and Reset command must be issued to return the device to read mode (see Write to
Buffer and Program in the commands section).
gives a
41/90