M29W640GT70NA6E NUMONYX, M29W640GT70NA6E Datasheet - Page 88

no-image

M29W640GT70NA6E

Manufacturer Part Number
M29W640GT70NA6E
Description
IC FLASH 64MBIT 70NS 48TSOP
Manufacturer
NUMONYX
Series
Axcell™r
Datasheet

Specifications of M29W640GT70NA6E

Format - Memory
FLASH
Memory Type
FLASH - Nor
Memory Size
64M (8Mx8, 4Mx16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TSOP
Cell Type
NOR
Density
64Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Top
Address Bus
23/22Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
8M/4M
Supply Current
10mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W640GT70NA6E
Manufacturer:
ST
Quantity:
9 215
Part Number:
M29W640GT70NA6E
Manufacturer:
Numonyx/ST Micro
Quantity:
1 915
Part Number:
M29W640GT70NA6E
Manufacturer:
NEC
Quantity:
2 037
Part Number:
M29W640GT70NA6E
Manufacturer:
ST
0
Part Number:
M29W640GT70NA6E
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
M29W640GT70NA6E
Quantity:
2 300
Appendix E
Figure 30. Write to Buffer and Program flowchart and pseudocode
1. n+1 is the number of addresses to be programmed.
2. A Write to Buffer and Program Abort and Reset must be issued to return the device in read mode.
3. When the block address is specified, any address in the selected block address space is acceptable. However when
4. DQ7 must be checked since DQ5 and DQ7 may change simultaneously.
5. If this flowchart location is reached because DQ5=’1’, then the Write to Buffer and Program command failed. If this
6. See
88/90
loading write buffer address with data, all addresses must fall within the selected write buffer page.
flowchart location is reached because DQ1=’1’, then the Write to Buffer and Program command aborted. In both cases, the
appropriate reset command must be issued to return the device in read mode: a Reset command if the operation failed, a
Write to Buffer and Program Abort and Reset command if the operation aborted.
Table 10
and
Table
11, for details on Write to Buffer and Program command sequence.
Flowchart
YES
NO
DQ1 = 1
NO
Check Status Register
to Flash Block Address
Read Status Register
Last Loaded Address
Last Loaded Address
Program Address Pair
(DQ1, DQ5, DQ7) at
FAIL OR ABORT
Write to Buffer F0h
Write Buffer Data,
Program Buffer
(DQ5, DQ7) at
Block Address
Block Address
Write Next Data,
Start Address
DQ7 = Data
DQ7 = Data
Abort Write
Command,
Write n
to Buffer
DQ5 = 1
X = X-1
X = 0
Start
YES
X=n
(4)
NO
NO
YES
NO
NO
(1)
,
(5)
YES
YES
(3)
YES
Program Aborted
Write to a Different
Write to Buffer and
Block Address
Write to Buffer and Program Command
END
First Part of the
(2)
AI12777

Related parts for M29W640GT70NA6E