21. Software Break
22. Number of Software Breakpoint and [Stop At] Settings in the [Run...] Menu
23. Note on RUN-TIME Display
24. Note on Displaying COMMUNICATION TIMEOUT ERROR
25. Note on Downloading Program
The maximum number of software breakpoints and [Stop At] settings allowed in the [Run...]
menu is 255. Therefore, when 255 software breakpoints are set, specification by [Stop At] in
the [Run...] menu becomes invalid. Use the software breakpoints and [Stop At] in the [Run...]
menu with 255 or less total settings.
The execution time of the user program displayed in the [Status] window is not a correct value
since the timer in the host computer has been used.
If COMMUNICATION TIMEOUT ERROR is displayed, the emulator cannot communicate
with the MCU. Select [Initialize] from the [File] menu to initialize the emulator. Before the
emulator is restarted, turn off the user system and disconnect the interface cable that has been
connected with the emulator.
In the [Load Program] dialog box, which is opened when [Load Program…] is selected, the
verify function is invalid. After downloading the program, perform verify in the [Verify S-
Record File with Memory] dialog box, which is opened when [Verify] is selected from the
[Memory] menu.
Session file
When the software breakpoint address set in the session file is H'0, the breakpoint will not
be set. If the address set as the breakpoint is wrong, the error message is not output. The
breakpoint is registered as DISABLE in the [Breakpoints] window.
Breakpoint cancellation
When the contents of the software breakpoint address is modified during user program
execution, the following message is displayed when the user program stops.
If the above message is displayed, cancel all software breakpoint settings with the [Delete
All] or [Disable] button in the [Breakpoints] window.
[Run program] dialog box
If an invalid software breakpoint address is specified as a stop address in the [Run
Program] dialog box, the invalid software breakpoint will become valid after the user
program has stopped.
[Breakpoints] window
During user program execution, it is impossible to jump from the breakpoint to the source
or address line on the [Source] or [Disassembly] window by using Go to Source in the
popup menu displayed on the [Breakpoints] window.
BREAKPOINT IS DELETED A=xxxxxxxx
169