EM260-RTY Ember, EM260-RTY Datasheet - Page 32

IC ZIGBEE SYSTEM-ON-CHIP 40-QFN

EM260-RTY

Manufacturer Part Number
EM260-RTY
Description
IC ZIGBEE SYSTEM-ON-CHIP 40-QFN
Manufacturer
Ember

Specifications of EM260-RTY

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
ZigBee™
Power - Output
-32dBm ~ 3dBm
Sensitivity
-97dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
30mA
Current - Transmitting
34mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
40-QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Other names
636-1003
EM260
32
120-1003-000D
3. Transmit the command:
4. Wait for nHOST_INT to assert.
5. Transmit and receive 0xFF until a byte other than 0xFF is received.
6. Receive response 0x00 (a byte other than 0xFF).
7. Receive the Error Byte and decode (0x02 is enumerated as RESET_POWERON).
8. Receive the Frame Terminator (0xA7).
9. Response 0x00 indicates the EM260 has reset and the Host should respond appropriately.
10. Deactivate Slave Select.
11. Since nHOST_INT does not assert again, there is no more data for the Host.
5.7.4
1. Activate nWAKE and activate timeout timer.
2. EM260 wakes up (if not already) and enables communication.
3. nHOST_INT asserts, indicating the EM260 can accept commands.
4. Host sees nHOST_INT activation within 3ms and deactivates nWAKE and timeout timer.
5. nHOST_INT deasserts immediately after nWAKE.
6. Activate Slave Select.
7. Transmit the Command 0x0A - SPI Protocol Version Request.
8. Transmit the Frame Terminator, 0xA7.
9. Wait for nHOST_INT to assert.
10. Transmit and receive 0xFF until a byte other than 0xFF is received.
0xFE
0x02
0x00
0x06
0xA7
Three-Part Transaction: Wake, Get Version, Stack Status Callback
SPI Byte indicating an EZSP Frame
Length Byte showing the EZSP Frame is 2 bytes long
EZSP Frame Control Byte indicating a command with no sleeping
EZSP Frame Type Byte indicating the
Frame Terminator
Figure 11. Timing Diagram of the Three-Part Transaction
callback