EM260-RTY Ember, EM260-RTY Datasheet - Page 60

IC ZIGBEE SYSTEM-ON-CHIP 40-QFN

EM260-RTY

Manufacturer Part Number
EM260-RTY
Description
IC ZIGBEE SYSTEM-ON-CHIP 40-QFN
Manufacturer
Ember

Specifications of EM260-RTY

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
ZigBee™
Power - Output
-32dBm ~ 3dBm
Sensitivity
-97dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
30mA
Current - Transmitting
34mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
40-QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Other names
636-1003
EM260
60
120-1003-000D
6.3.6
Name: channelCalibrated
Description: Tests whether the specified channel is calibrated.
Command Parameters:
int8u channel
Response Parameters:
EmberStatus status
Name: startChannelCalibration
Description: Start calibrating the specified channel. The calibration process takes several seconds to com-
plete and the EM260 will be unresponsive until it is complete. The Host must not send another command until
the EM260 indicates that calibration is complete, using the
Command Parameters:
int8u channel
Response Parameters:
EmberStatus status
Name: calibrationCompleteHandler
Description: Informs the Host that calibration is complete and reports the result of the calibration.
This frame is a response to the
Response Parameters:
int8u channel
EmberStatus status
Networking Frames
callback
command.
The channel number to test.
EMBER_SUCCESS. The Host must wait for the
ID: 0x4B
EMBER_SUCCESS if the channel is calibrated, EM-
BER_CHANNEL_NOT_CALIBRATED if the channel is not calibrated
and EMBER_PHY_INVALID_CHANNEL if the channel is not a valid
802.15.4 channel.
ID: 0x4C
The channel to be calibrated.
pleteHandler
ID: 0x4D
The channel that was calibrated.
EMBER_SUCCESS if the channel was calibrated successfully and
EMBER_PHY_INVALID_CHANNEL if the channel was not a valid
802.15.4 channel.
calibrationCompleteHandler
callback to report the result of the calibration.
calibrationCom-
callback.

Related parts for EM260-RTY