EM260-RTY Ember, EM260-RTY Datasheet - Page 70

IC ZIGBEE SYSTEM-ON-CHIP 40-QFN

EM260-RTY

Manufacturer Part Number
EM260-RTY
Description
IC ZIGBEE SYSTEM-ON-CHIP 40-QFN
Manufacturer
Ember

Specifications of EM260-RTY

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
ZigBee™
Power - Output
-32dBm ~ 3dBm
Sensitivity
-97dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
30mA
Current - Transmitting
34mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
40-QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Other names
636-1003
EM260
70
120-1003-000D
Name: getBinding
Description: Gets an entry from the binding table.
Command Parameters:
int8u index
Response Parameters:
EmberStatus status
EmberBindingTableEntry value
Name: deleteBinding
Description: Deletes a binding table entry.
Command Parameters:
int8u index
Response Parameters:
EmberStatus status
Name: bindingIsActive
Description: Indicates whether a binding table entry is active - that is, whether a connection to it is open or
any messages are en route from it. Note that this command does not indicate whether a binding is clear. To
determine whether a binding is clear, check whether the type field of the EmberBindingTableEntry has the
value EMBER_UNUSED_BINDING.
Command Parameters:
int8u index
Response Parameters:
boolean active
The index of a binding table entry.
The index of a binding table entry.
The index of a binding table entry.
ID: 0x2C
An EmberStatus value indicating success or the reason for fail-
ure.
The contents of the binding entry.
ID: 0x2D
An EmberStatus value indicating success or the reason for fail-
ure.
ID: 0x2E
True if the binding table entry is active. False if the binding
table entry is not active.

Related parts for EM260-RTY