EM260-RTY Ember, EM260-RTY Datasheet - Page 47

IC ZIGBEE SYSTEM-ON-CHIP 40-QFN

EM260-RTY

Manufacturer Part Number
EM260-RTY
Description
IC ZIGBEE SYSTEM-ON-CHIP 40-QFN
Manufacturer
Ember

Specifications of EM260-RTY

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
ZigBee™
Power - Output
-32dBm ~ 3dBm
Sensitivity
-97dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
30mA
Current - Transmitting
34mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
40-QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Other names
636-1003
EmberStatus
EMBER_MAC_NO_ACK_RECEIVED
EMBER_MAC_INDIRECT_TIMEOUT
EMBER_SIM_EEPROM_ERASE_PAGE_GREEN
EMBER_SIM_EEPROM_ERASE_PAGE_RED
EMBER_SIM_EEPROM_FULL
EMBER_SIM_EEPROM_FLASH_WRITE_FAILED
EMBER_SIM_EEPROM_INIT_1_FAILED
EMBER_SIM_EEPROM_INIT_2_FAILED
EMBER_SIM_EEPROM_INIT_3_FAILED
EMBER_ERR_TOKEN_UNKNOWN
0x40
0x42
0x43
0x44
0x45
0x46
0x47
0x48
0x49
0x4B
We expected to receive an ACK following the
transmission, but the MAC level ACK was never
received.
Indirect data message timed out before polled.
The Simulated EEPROM is telling the application
that there is at least one flash page to be erased.
The GREEN status means the current page has not
filled above the ERASE_CRITICAL_THRESHOLD. The
application should call the function
halSimEepromErasePage()
page.
The Simulated EEPROM is telling the application
that there is at least one flash page to be erased.
The RED status means the current page has filled
above the ERASE_CRITICAL_THRESHOLD. Due to
the shrinking availability of write space, there is a
danger of data loss. The application must call the
function
possible to erase a page.
The Simulated EEPROM has run out of room to
write any new data and the data trying to be set
has been lost. This error code is the result of
ignoring the SIM_EEPROM_ERASE_PAGE_RED error
code. The application must call the function
halSimEepromErasePage()
further calls to set a token.
A fatal error has occurred while trying to write
data to the Flash and the write verification has
failed. The data in the flash cannot be trusted
after this error, and it is possible this error is the
result of exceeding the life cycles of the flash.
Attempt 1 to initialize the Simulated EEPROM has
failed. This failure means the information already
stored in Flash (or a lack thereof), is fatally
incompatible with the token information compiled
into the code image being run.
Attempt 2 to initialize the Simulated EEPROM has
failed. This failure means Attempt 1 failed, and
the token system failed to properly reload default
tokens and reset the Simulated EEPROM.
Attempt 3 to initialize the Simulated EEPROM has
failed. This failure means one or both of the
tokens TOKEN_MFG_NVDATA_VERSION or TO-
KEN_STACK_NVDATA_VERSION were incorrect and
the token system failed to properly reload default
tokens and reset the Simulated EEPROM.
An unknown flash token was specified.
halSimEepromErasePage()
when it can to erase a
to make room for any
120-1003-000D
EM260
as soon as
47