E8MS-N0 Omron, E8MS-N0 Datasheet - Page 11

SENSOR PRESSURE NEGATIV 0-101KPA

E8MS-N0

Manufacturer Part Number
E8MS-N0
Description
SENSOR PRESSURE NEGATIV 0-101KPA
Manufacturer
Omron
Series
E8MSr
Datasheets

Specifications of E8MS-N0

Pressure Type
Gauge
Operating Pressure
-14.65 ~ +0 PSI, -101 ~ 0 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Sensor Output
Voltage
Supply Current
25mA
Voltage Rating
12V
Port Style
NPT, M5
Pressure Measurement Type
Gage
Operating Pressure Min
0psi
Terminal Type
Connector
Operating Pressure Max
14.6psi
Mounting Style
Desktop
Maximum Operating Temperature
+ 50 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
12 V
Output Voltage
1 V to 5 V
Pressure Port
Y
Sensor Type
Sensors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E8MSN0
J SETTINGS
1. Turning ON the Power
2. Channel Selection
3. Sensor Type Selection
E8M/E8MS
The Controller in pressure sensing operation requires basic
settings, such as Pressure Sensor type and measurement
unit settings as described in the procedure below.
Turn ON the K3C after making sure that the Sensors and
power supply to be used are properly connected to the
Controller.
Four Pressure Sensors can be connected to the K3C, one of
which can be selected with the K3C for measurement value
display.
CH1 to CH4 correspond to the four Pressure Sensors
respectively.
The K3C displays the measurement value of channel 1 right
after the K3C is turned ON.
Press the CH Key to select the channel to be used. A
channel is selected in the sequence 1 → 2 → 3 → 4 by
repeatedly pressing the CH Key.
Channel 1 is selected right after the K3C is turned ON. Select
the channel where the Sensor to be used is connected. After
the channel is selected, set the Sensor type and
measurement unit.
Press the MENU Key four times so that “SEN” will appear.
If the display does not change when the MENU Key is
pressed, the key-protect function may be enabled. Refer to
Key-protect Settings (found in the Advanced Operations
Sub-Section) and disable the key-protect function.
Press the MENU
Key four times.
The Sensor on channel 1 is in operation.
The measurement value
appears right after the
K3C is turned ON.
Press the CH Key.
The next channel is selected.
The display changes.
The default unit is kPa.
12
4. Measurement Unit Selection
Note: Selectable measurement units vary with the Sensor type.
Select the Sensor type according to the target object.
The following Sensor types are available.
Press the DISPLAY Key once.
A Sensor type appears in the main display.
The sensor indicator for the selected Sensor type flashes.
Press the Up or Down Key to select the Sensor type
according to the Sensor to be used.
After selecting the Sensor type, press the MENU Key once to
enter the Sensor type.
The main display will change to “SET.”
Press the MENU Key once. The main display will change to
“UNT” from “SET.”
Press the DISPLAY Key once.
A measurement unit will appear in the main display.
Press the Up or Down Key to select the measurement unit to
be used.
Press the DISPLAY
Key once.
Press the Up or Down Key.
Press the MENU
Key once.
Press the MENU
Key once.
Press the DISPLAY
Key once.
Press the Up or Down Key.
Any measurement unit that cannot be selected will be
skipped.
E8M-A1
E8MS-N0
E8M-N0
E8MS-10
E8M-10
Not connected
E8MS-01
The LED display of the selected unit is lit.
The LED display of the selected unit is lit.
Model
The display changes to “SET.”
The display changes to “UNT.”
Measurement unit appears.
A preset Sensor type appears.
The Sensor type changes.
- - 1
- - 101
1000
---
100
Display
E8M/E8MS