E8MS-N0 Omron, E8MS-N0 Datasheet - Page 17

SENSOR PRESSURE NEGATIV 0-101KPA

E8MS-N0

Manufacturer Part Number
E8MS-N0
Description
SENSOR PRESSURE NEGATIV 0-101KPA
Manufacturer
Omron
Series
E8MSr
Datasheets

Specifications of E8MS-N0

Pressure Type
Gauge
Operating Pressure
-14.65 ~ +0 PSI, -101 ~ 0 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Sensor Output
Voltage
Supply Current
25mA
Voltage Rating
12V
Port Style
NPT, M5
Pressure Measurement Type
Gage
Operating Pressure Min
0psi
Terminal Type
Connector
Operating Pressure Max
14.6psi
Mounting Style
Desktop
Maximum Operating Temperature
+ 50 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
12 V
Output Voltage
1 V to 5 V
Pressure Port
Y
Sensor Type
Sensors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E8MSN0
J ON- AND OFF-POINT SIMPLE SETTING (BY TEACHING)
ON- and OFF-point values can be set by using measurement values instead of key input in the teaching mode.
One-point teaching, which has only one setting point, and two-point teaching, which has two setting points, are both available in the
teaching mode.
Changing to Teaching Mode
The Controller will go into teaching mode by pressing the TEACH Key for 1 s in measurement mode.
Menu Selection
Two-point teaching (i.e., hysteresis mode teaching) or one-point teaching (i.e., window mode teaching) can be selected by pressing the DIS-
PLAY Key.
By pressing the DISPLAY Key again, OUT2 will be ready for setting for channel 1 only.
Displayed items:
TH1 (teach hysteresis mode, first point)
TW (teach window mode)
E8M/E8MS
One-point Teaching
Two-point teaching mode
(hysteresis mode teaching)
Pressure
1 s
One-point teaching mode
(window mode teaching)
18
Two-point Teaching
Pressure
E8M/E8MS

Related parts for E8MS-N0