E8MS-N0 Omron, E8MS-N0 Datasheet - Page 13

SENSOR PRESSURE NEGATIV 0-101KPA

E8MS-N0

Manufacturer Part Number
E8MS-N0
Description
SENSOR PRESSURE NEGATIV 0-101KPA
Manufacturer
Omron
Series
E8MSr
Datasheets

Specifications of E8MS-N0

Pressure Type
Gauge
Operating Pressure
-14.65 ~ +0 PSI, -101 ~ 0 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Sensor Output
Voltage
Supply Current
25mA
Voltage Rating
12V
Port Style
NPT, M5
Pressure Measurement Type
Gage
Operating Pressure Min
0psi
Terminal Type
Connector
Operating Pressure Max
14.6psi
Mounting Style
Desktop
Maximum Operating Temperature
+ 50 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
12 V
Output Voltage
1 V to 5 V
Pressure Port
Y
Sensor Type
Sensors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E8MSN0
Basic Set Mode
The K3C is in measurement mode right after it is turned ON.
Press the MENU Key once to change the mode to the basic setting mode. “SET” will appear in the main display. If the mode does not
change, the key-protect function may be enabled.
ON- and OFF-point Settings
Set ON- and OFF-points for each channel.
Note: 1. The output method varies with the ON and OFF-point settings.
1. Press the DISPLAY Key in basic setting mode with “SET” displayed so that the OUT1 indicator will flash and the ON-point indicator
2. Press the DISPLAY Key so that the OUT1 indicator will flash and the OFF-point indicator will be lit.
3. Press the DISPLAY Key so that the OUT2 indicator will flash and the ON-point indicator will be lit.
4. Press the DISPLAY Key so that the OUT2 indicator will flash and the OFF-point indicator will be lit.
5. The set values will be entered when the MENU Key is pressed and “UNT” will appear.
Note: If the RST/ESC Key is pressed instead, the set values will not be entered, and “SET” will appear.
When the OUT1 settings are finished and the DISPLAY Key is pressed, OUT2 will be ready for setting only with the channel that has
OUT2 output.
E8M/E8MS
Measurement Mode
The Controller will be in hysteresis mode if the ON-point set
value is larger than the OFF-point set value.
The Controller will be in window mode if the OFF-point set
value is larger than the ON-point set value.
The Controller will not be in ON/OFF operation if the ON-
point value is the same as the OFF-point set value.
will be lit.
Press the Up or Down Key to change the ON-point set value of OUT1.
Press the Up or Down Key to change the OFF-point set value of OUT1.
Press the UP or Down Key to change the ON-point set value of OUT2.
Press the UP or Down Key to change the OFF-point set value of OUT2.
2. When using the E8M-A1 Minute Differential Pressure Sensor, both the ON point and OFF point must be set to the negative
setting. (They cannot be set to the positive setting.)
Basic Set Mode
14
E8M/E8MS