SENSOR PRESSURE NEGATIV 0-101KPA

E8MS-N0

Manufacturer Part Number
E8MS-N0
Description
SENSOR PRESSURE NEGATIV 0-101KPA
Manufacturer
Omron
Series
E8MSr
Datasheets

Specifications of E8MS-N0

Pressure Type
Gauge
Operating Pressure
-14.65 ~ +0 PSI, -101 ~ 0 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Sensor Output
Voltage
Supply Current
25mA
Voltage Rating
12V
Port Style
NPT, M5
Pressure Measurement Type
Gage
Operating Pressure Min
0psi
Terminal Type
Connector
Operating Pressure Max
14.6psi
Mounting Style
Desktop
Maximum Operating Temperature
+ 50 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
12 V
Output Voltage
1 V to 5 V
Pressure Port
Y
Sensor Type
Sensors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E8MSN0
J DISPLAYS OF SETTINGS AND MEASUREMENTS
Digital Display
The E8M displays alphanumeric characters,such as measurement
values and menu items, with 7-segment LEDs as shown below for
example.
J MODES
In addition to a measurement value display function, the K3C has a variety of functions including an external device control function.
These functions are available in four main modes as described below, where characters in parentheses indicate the digital display condi-
tions. For the relationship among each mode and for switching methods, refer to the following figure.
E8M/E8MS
Display
set
kpa
wid
aUe
Meaning
ON and OFF-point Settings
Unit (kPa)
Width
Average
Power ON
Measurement
mode
10
The following abbreviations are used for the digital display of the
Controller.
Abbreviation
SET
UNT
OPE
SEN
PRT
COP
HYS
WID
AUT
DSP
AVE
1 s min.
Meaning
Setting
Unit
Operation
Sensor
Protect
Copy
Hysteresis
Width
Auto
Display
Average
Special
setting mode
Basic setting
mode
Teaching
mode
E8M/E8MS

Related parts for E8MS-N0