E8MS-N0 Omron, E8MS-N0 Datasheet - Page 12

SENSOR PRESSURE NEGATIV 0-101KPA

E8MS-N0

Manufacturer Part Number
E8MS-N0
Description
SENSOR PRESSURE NEGATIV 0-101KPA
Manufacturer
Omron
Series
E8MSr
Datasheets

Specifications of E8MS-N0

Pressure Type
Gauge
Operating Pressure
-14.65 ~ +0 PSI, -101 ~ 0 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Sensor Output
Voltage
Supply Current
25mA
Voltage Rating
12V
Port Style
NPT, M5
Pressure Measurement Type
Gage
Operating Pressure Min
0psi
Terminal Type
Connector
Operating Pressure Max
14.6psi
Mounting Style
Desktop
Maximum Operating Temperature
+ 50 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
12 V
Output Voltage
1 V to 5 V
Pressure Port
Y
Sensor Type
Sensors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E8MSN0
Refernce Table for Sensor Types and Availability of Measurement Units
Note: Select Uol for voltage display.
J OUTPUT CONTROL
The K3C has output according to the measurement value. The output can be used to control external devices, such as valves and absorption
systems.
To control an external device, a reference value must be set so that the output can be turned ON if the measurement value is above the refer-
ence value and turned OFF if the measurement value is below the reference value. (The ON/OFF setting can be reversed.)
The value turning the outputON is called the ON pointand the value turning the outputOFF is called the OFF point.The following is an example
of ON- and OFF-point settings on condition that the Controller has normally open output.
Normally Open Output
Normally Closed Output
Select the channel where the data is to be set.
E8M/E8MS
Hysteresis Mode
Hysteresis Mode
Sensor type
Sensor type
E8MS-N0
E8M-N0
E8MS-10
E8M-10
E8M-A1
E8MS-01
After the measurement unit is selected, press the MENU Key
to enter the measurement unit.
The display will change to “OPE.”
A channel is selected in sequence by repeatedly pressing the CH Key.
Data can be set on each channel independently.
Be sure that the channel to be set is correct.
Press the MENU
Key once.
OFF set
value
OFF set
value
Pressure range
Pressure range
0 to - - 101 kPa
0 to 1 MPa
0 to - - 1,000 Pa
0 to 100 kPa
ON set
value
ON set
value
Pressure
The display changes to
“OPE.”
Pressure
Display unit
kpa (kPa)
Yes
Yes
Yes
Yes
kgf (kgf/cm
Yes
Yes
No
Yes
13
2
Window Mode
)
Window Mode
Press the RST/ESC Key.
The measurement value will appear in a present setting. This
state is called the “measurement mode.”
The basic settings are complete.
Press the RST/ESC
Key once.
hg (mmHg)
Yes
No
No
No
ON set
value
ON set
value
OFF set
value
OFF set
value
h2o (mmH
No
No
Yes
No
Pressure
Pressure
The present measurement
value appears.
2
O)
Uol (vol)
(see note)
Yes
Yes
Yes
Yes
E8M/E8MS

Related parts for E8MS-N0