E8MS-N0 Omron, E8MS-N0 Datasheet - Page 22

SENSOR PRESSURE NEGATIV 0-101KPA

E8MS-N0

Manufacturer Part Number
E8MS-N0
Description
SENSOR PRESSURE NEGATIV 0-101KPA
Manufacturer
Omron
Series
E8MSr
Datasheets

Specifications of E8MS-N0

Pressure Type
Gauge
Operating Pressure
-14.65 ~ +0 PSI, -101 ~ 0 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Sensor Output
Voltage
Supply Current
25mA
Voltage Rating
12V
Port Style
NPT, M5
Pressure Measurement Type
Gage
Operating Pressure Min
0psi
Terminal Type
Connector
Operating Pressure Max
14.6psi
Mounting Style
Desktop
Maximum Operating Temperature
+ 50 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
12 V
Output Voltage
1 V to 5 V
Pressure Port
Y
Sensor Type
Sensors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E8MSN0
Automatic Compensation of Set Value for Original Pressure Fluctuation
When using the K3C-MP8-T1Z 4-channel model, the set values on channels 2 through 4 can be compensated according to the original
pressure fluctuation that is input to channel 1. When using the K3C-DP8-TIZ 2-channel model, the CH2 setting can be compensated.
Compensation value = Original pressure fluctuation (%) x compensation coefficient
Compensation is performed every minute by comparing the one-minute mean value and reference value of the original pressure.
The reference value is the mid-value between the ON- and OFF-points of OUT 1 on channel 1.
1. The compensation coefficient will appear by pressing the DISPLAY Key.
2. Select the channel for value compensation.
3. On the basis of no compensation as 0 times, change the compensation coefficient with the Up or Down Key within a range between 0
4. The compensation coefficient is entered and “HYS” will appear by pressing the MENU Key.
Note: 1. Channel 1 will be skipped in the original pressure compensation menu.
Hysteresis Width Change
Hysteresis width change is possible as shown below.
1. The hysteresis width set value will appear by pressing the DISPLAY Key.
2. Select the channel where hysteresis width change is required with the CH Key.
3. Press the Up or Down Key to change the set value within a range between 0.1% and 10.0% FS.
4. The set value will be entered and “WID” will appear by pressing the MENU Key.
Note: 1. The above settings in hysteresis mode will be invalid if data is set in the menu while “SET” is displayed. The above settings in
E8M/E8MS
Hysteresis Mode
to 10 times.
If the RST/ESC Key is pressed after a compensation coefficient change, the new compensation coefficient will be canceled and “AUT”
will appears.
If the RST/ESC Key is pressed, set value change will be canceled and “HYS” will appear.
2. When using the K3C-DP8-TIZ 2-channel model, the compensation coefficient setting is common to OUT1 and OUT2.
2. The width between the ON and OFF points are used as the hysteresis width in hysteresis mode. Therefore, the settings cannot
3. By pressing the DISPLAY Key after OUT1 is displayed, the display will change to OUT2 only with the channel that has OUT2
hysteresis mode will be valid only if data is set by teaching. The above settings in window mode are valid in measurement
mode.
be changed in the above steps.
output.
OFF point
Channel selection
with the CH Key.
ON point
Changinghysteresis
width
Pressure
Compensation coefficient change
with the Up or Down Key.
Cancel
23
Enter
Window Mode
ON point
OFF point
Pressure
Changinghysteresis
width
E8M/E8MS