Specifications of E8MS-N0

Pressure Type
Gauge
Operating Pressure
-14.65 ~ +0 PSI, -101 ~ 0 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Sensor Output
Voltage
Supply Current
25mA
Voltage Rating
12V
Port Style
NPT, M5
Pressure Measurement Type
Gage
Operating Pressure Min
0psi
Terminal Type
Connector
Operating Pressure Max
14.6psi
Mounting Style
Desktop
Maximum Operating Temperature
+ 50 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
12 V
Output Voltage
1 V to 5 V
Pressure Port
Y
Sensor Type
Sensors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E8MSN0
Two-point Teaching (Hysteresis Mode Teaching)
1. By pressing the TEACH Key at the point of status 1 as shown below, the present measurement value of the selected channel will
2. Check the measurement value and press the TEACH Key for teaching. Teaching will be completed on the first point.
3. By pressing the TEACH Key at the point of status 2 as shown below, the present measurement value will appear.
4. Check the measurement value and press the TEACH Key for teaching. Teaching will be completed on the second point.
5. Press the RST/ESC Key so that the Controller will be in measurement mode.
Note: The Controller will be in hysteresis mode automatically after two-point teaching.
The above settings are useful for applications that check vacuum absorption.
E8M/E8MS
appear.
Two-point Teaching
ON point = (Teach 1 + Teach 2) ÷ 2
OFF point = ON point - - 3% FS
Default is 3% FS (can be changed).
Status 1
OFF point
ON-point and
OFF-point indicators
flash.
ON point
Status 2
Pressure
Present
measurement value
appears.
Present
measurement value
appears.
The value of teach 1
can be larger than that
of teach 2 and vice
versa. The teach 1 and
2 positions are
reversible.
Teaching completed
on the first point.
Teaching completed
on the second point.