SENSOR PRESSURE NEGATIV 0-101KPA

E8MS-N0

Manufacturer Part Number
E8MS-N0
Description
SENSOR PRESSURE NEGATIV 0-101KPA
Manufacturer
Omron
Series
E8MSr
Datasheets

Specifications of E8MS-N0

Pressure Type
Gauge
Operating Pressure
-14.65 ~ +0 PSI, -101 ~ 0 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Sensor Output
Voltage
Supply Current
25mA
Voltage Rating
12V
Port Style
NPT, M5
Pressure Measurement Type
Gage
Operating Pressure Min
0psi
Terminal Type
Connector
Operating Pressure Max
14.6psi
Mounting Style
Desktop
Maximum Operating Temperature
+ 50 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
12 V
Output Voltage
1 V to 5 V
Pressure Port
Y
Sensor Type
Sensors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E8MSN0
Number of Measurement Times Setting Change for Measurement Value Averaging
One of the following number of times can be selected: 1, 8, 32, and 256
1. The number of measurement times set value will appear by pressing the DISPLAY Key.
2. Press the Up or Down Key to change the set value.
3. The set value will be entered and “PRT” will appear by pressing the MENU Key.
Note: If 0.5 is set while “DSP” is displayed and 32 is set while “AVE” is displayed, pressure will be measured 32 times and averaged as a
E8M/E8MS
If the RST/ESC Key is pressed, set value change will be canceled and “AVE” will appear.
block. The averaged blocks as a mean value will be displayed and refreshed every 0.5 s.
Value change with
the Up or Down Key.
Value change with
the Up or Down Key.
Cancel
Cancel
25
Enter
Enter
E8M/E8MS