Miscellaneous Features Register (Register 16)
Interrupt Control/Status Register (Register 17)
Reg
Reg
16
16
16
16
16
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
12:4
Bit
3:0
Bit
15
14
13
15
14
13
12
10
11
9
8
7
6
5
4
3
2
1
0
Link_Not_OK_ IE
A_Neg_Comp Int
Link_Not_OK Int
ANeg_Comp_IE
Page_Rx_Int
PD_Fault_Int
INTR_LEVL
Page_Rx_IE
PD_Fault_IE
LP_Ack_Int
R_Fault_Int
LP_Ack_IE
R_Fault_IE
Jabber_Int
Reserved
Reserved
Reserved
Jabber_IE
Rx_Er_Int
Rx_Er_IE
TXJAM
Name
Name
Table 16. Miscellaneous Features Register (Register 16)
Table 17. Interrupt Control/Status Register (Register 17)
Description
Write as 0; 1 = factory use only.
1 = INT is forced to 1 to signal an interrupt.
0 = INT is forced to 0 to signal an interrupt.
1 = Force CIM to send jam pattern.
0 = Normal operation mode.
Write as 0, ignore when read.
Ignore when read.
Parallel Detection Fault Interrupt Enable.
This bit is set when RX_ER transitions high.
Description
Jabber Interrupt Enable.
Receive Error Interrupt Enable.
Page Received Interrupt Enable.
Link Partner Acknowledge Interrupt Enable.
Link Status Not OK Interrupt Enable.
Remote Fault Interrupt Enable.
Auto-Negotiation Complete Interrupt Enable.
This bit is set when a jabber event is detected.
This bit is set when a new page is received from link partner during
Auto-Negotiation.
This bit is set when parallel detect fault is detected.
This bit is set when the FLP with acknowledge bit set is received.
This bit is set when link status switches from OK status to Non-OK
status (Fail or Ready).
This bit is set when remote fault is detected.
This bit is set when Auto-Negotiation is complete.
Am79C875
Read/
Write
RW
RW
RW
RO
RO
Read/
Write
RW
RW
RW
RW
RW
RW
RW
RW
RC
RC
RC
RC
RC
RC
RC
RC
Default
00000
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
31