Table 30. PRT CONTINUOUS Mode Operation Example
Reading the Current Count Value
The CPU is capable of reading the current count value while the timer is running. This
Read event does not affect timer operation. The High byte of the current count value is
latched during a Read of the Low byte.
Timer Interrupts
The timer interrupt flag, PRT_IRQ, is set to 1 whenever the timer reaches its end-of-count
value,
CONTINUOUS mode. The interrupt flag is only set when the timer reaches
reloads) from
the value
The CPU can be programmed to poll the PRT_IRQ bit for the time-out event. Alterna-
tively, an interrupt service request signal can be sent to the CPU by setting IRQ_EN to 1.
Then, when the end-of-count value,
interrupt service request signal is passed to the CPU. PRT_IRQ is cleared to 0 and the
interrupt service request signal is inactivated whenever the CPU reads from the timer con-
trol registers, TMRx_CTL.
Timer Input Source Selection
Timers 0–3 feature programmable input source selection. By default, the input is taken
from the eZ80L92’s system clock. Alternatively, Timers 0–3 can take their input from port
input pins PB0 (Timers 0 and 2) or PB1 (Timers 1 and 3). Timers 0–3 can also use the
Real-Time Clock clock source (50, 60, or 32768 Hz) as their clock sources. When the
timer clock source is the Real-Time Clock signal, the timer decrements on the second
rising edge of the system clock following the falling edge of the RTC_X
input source for these timers is set using the Timer Input Source Select register.
Parameter
PRT Enabled
Reload and Restart Enabled
PRT Clock Divider = 4
CONTINUOUS Mode
PRT Interrupt Enabled
PRT Reload Value
0000h
0000h
, in SINGLE PASS mode, or when the timer reloads the start value in
0001h
, which selects the maximum time-out period.
. The timer interrupt flag is not set to 1 when the timer is loaded with
0000h
Control Register(s)
TMRx_CTL[0]
TMRx_CTL[1]
TMRx_CTL[3:2]
TMRx_CTL[4]
TMRx_CTL[6]
{TMRx_RR_H, TMRx_RR_L}
, is reached and PRT_IRQ is set to 1, an
Programmable Reload Timers
Product Specification
OUT
eZ80L92 MCU
0000h
pin. The
0004h
Value
00b
1
1
1
1
(or
80