Pulse Outputs
One-shot Pulse Output (STIM(980))
Pulse Counter Timer Function (STIM(980))
188
Mode settings for
ports 1 and 2
System Setup
Pulse output
mode
1,2,3...
1,2,3...
Note
INI
Single-phase pulse output
with trapezoidal
acceleration/deceleration
Ladder program
2. Wire the output.
3. Make the necessary System Setup settings (Pulse Output Tab Page − Op-
4. Create the necessary ladder programming.
1. Determine pulse output port.
2. Wire the output.
3. Make the necessary System Setup settings.
4. Create the necessary ladder programming.
The STIM(980) one-shot pulse output function can be used at the same time
as an STIM(980) timer interrupt function (one-shot timer or scheduled timer).
1. Determine pulse output port.
2. Make the necessary System Setup settings.
• Select pulse output 1 or 2.
• Output: CW and CCW
• Output power supply: 5 V DC
• Set the pulse output operation mode (in the Pulse Output Tab Page −
• Set the clock speed for pulse outputs 1 and 2.
• Use PLS2(887) to start pulse output control with trapezoidal acceleration/
• Use INI(880) to stop pulse output from the specified port.
• Use PRV(881) to read the pulse output PV of the specified port.
• Select pulse output 1 or 2.
• Set the pulse output operation mode (in the Pulse Output Tab Page −
• Use STIM(980) (with C1 = #0001 or #0002) to turn ON the one-shot pulse
• Select pulse output 1 or 2.
MODE CONTROL
Stop pulse output.
eration Mode).
Operation Mode) to relative pulse output or absolute linear pulse output.
deceleration from the specified port (acceleration and deceleration are
specified separately).
Operation Mode) to 1 shot.
output.
Refresh status (once each cycle
just after instruction execution)
Pulse output status
Port 1
Port 2
PULSE
OUTPUT
PLS2
A624
A625
Set number of output pulses.
Target frequency: 20 Hz to 1 MHz
Starting frequency: 0 Hz to 1 MHz
Acceleration/deceleration rates
(set separately)(1 or 2 ms cycle,
Start pulse output.
1 Hz to 9,999 Hz)
Ladder program
Refresh PV (once each cycle)
Start
output
Port 1
Port 2
Pulse output PV
A621
A623
A620
A622
Refresh PV (immediate refresh)
Read pulse output PV
PRV
CCW
CCW
CW
CW
Pulse output
port 1
Pulse output
port 2
HIGH-SPEED
COUNTER
PV READ
Section 7-6