Inspections
10-1 Inspections
10-1-1 Inspection Points
Inspection Points for Periodic Inspections
260
1
2
3
No.
Source Power
Supply
I/O Power Sup-
ply
Ambient environ-
ment
Item
Check for voltage fluctuations
at the power supply terminals.
Check for voltage fluctuations
at the I/O terminals.
Check the ambient tempera-
ture. (Inside the control panel
if the FQM1 is in a control
panel.)
Check the ambient humidity.
(Inside the control panel if the
FQM1 is in a control panel.)
Check that the FQM1 is not in
direct sunlight.
Check for accumulation of
dirt, dust, salt, metal filings,
etc.
Check for water, oil, or chemi-
cal sprays hitting the FQM1.
Check for corrosive or flam-
mable gases in the area of the
FQM1.
Check the level of vibration or
shock.
Check for noise sources near
the FQM1
Inspection
Daily or periodic inspections are required in order to maintain the FQM1 in
peak operating condition.
Although the major components in the FQM1 have an extremely long life time,
they can deteriorate under improper environmental conditions. Periodic
inspections are thus required to ensure that the required condition is being
maintained.
Inspection is recommended at least once every six months to a year, but more
frequent inspections will be necessary in adverse environments.
Take immediate steps to correct the situation if any of the conditions in the fol-
lowing table are not met.
The voltage must be within
the allowable voltage fluctu-
ation range.
(See note.)
Voltages must be within
specifications for each
Module.
0 to 55°C
Relative humidity must be
10% to 90% with no con-
densation.
Not in direct sunlight
No accumulation
No spray on the FQM1
No corrosive or flammable
gases
Vibration and shock must
be within specifications.
No significant noise
sources
Criteria
Use a voltage tester to check the
power supply at the terminals. Take
necessary steps to bring voltage
fluctuations within limits.
Use a voltage tester to check the
power supply at the terminals. Take
necessary steps to bring voltage
fluctuations within limits.
Use a thermometer to check the
temperature and ensure that the
ambient temperature remains
within the allowed range of 0 to
55°C.
Use a hygrometer to check the
humidity and ensure that the ambi-
ent humidity remains within the
allowed range.
In particular, verify that there is no
condensation or icing caused by
sudden temperature changes.
Protect the FQM1 if necessary.
Clean and protect the FQM1 if nec-
essary.
Clean and protect the FQM1 if nec-
essary.
Check by smell or use a sensor.
Install cushioning or shock absorb-
ing equipment if necessary.
Either separate the FQM1 and
noise source or protect the FQM1.
Action
Section 10-1