XW2Z-100J-B9 Omron, XW2Z-100J-B9 Datasheet - Page 269

no-image

XW2Z-100J-B9

Manufacturer Part Number
XW2Z-100J-B9
Description
SERVO DRV+G8R CONNECTING CABLES
Manufacturer
Omron
Datasheet

Specifications of XW2Z-100J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z100JB9
Error Processing
9-2-5
CPU Errors
CPU Standby
Fatal Errors
246
Stopped
Stopped
Operating
Operating
status
status
Error Tables
CPU
error
CPU
standby
name
name
Error
Error
None
None
in Auxiliary
in Auxiliary
Error flags
Error flags
Area
Area
Note Always confirm the safety of connected equipment before turning the power
The following tables show the errors which can occur in the FQM1 and indi-
cate the probable cause of the errors.
supply OFF or ON.
If the following LED indicator condition appears during operation (in RUN or
MONITOR mode), it indicates that a CPU error has occurred. The CX-Pro-
grammer cannot be connected if a CPU error has occurred.
If a fatal error occurs, the RDY and ERR indicators will be lit and the RUN indi-
cator will be OFF, but a CX-Programmer can be connected. This difference
can be used to distinguish between a CPU error and other fatal errors.
If the following LED indicator condition appears when the power is turned ON,
it indicates that the FQM1 is in CPU standby status.
When the FQM1 is turned ON, cyclic servicing starts after the Coordinator
Module recognizes all of the connected Motion Control Modules. Operation
can be started at that point.
If the startup mode is RUN or MONITOR mode, the FQM1 will remain in
standby status until all of the Motion Modules have been recognized..
If the following LED indicator condition appears during operation (in RUN or
MONITOR mode), it indicates that a fatal error has occurred..
The fatal error’s error contents will be displayed in the Error Tab in the CX-Pro-
grammer’s Error Window. Determine the cause of the error from the error
Unit Indicators
Unit Indicators
Unit Indicators
None
None
Error code
Error code
Power Supply
Power Supply
Power Supply
(in A400)
(in A400)
POWER
POWER
POWER
Lit
Lit
Lit
None
None
Error con-
Error con-
tents
tents
RDY
OFF
RDY
OFF
RDY
Lit
A WDT (watchdog timer)
error occurred in a Module.
(This error does not nor-
mally occur)
A Motion Control Module
has not started properly.
Probable cause
Probable cause
RUN
RUN
RUN
OFF
OFF
OFF
Module Indicators
Module Indicators
Module Indicators
ERR
ERR
ERR
OFF
Lit
Lit
PRPHL
PRPHL
PRPHL
---
---
---
Turn the power OFF and
restart. The Module may be
damaged. Contact your
OMRON representative.
Replace the Motion Control
Module.
COMM1
COMM1
COMM1
Remedy
Remedy
---
---
---
Section 9-2
COMM2
COMM2
COMM2
---
---
---