340
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
A608
Address
00
01
02
03
04
05
06
07
08
09 to 11
12
13 to 15
Bits
High-speed
counter 1 status
Name
Target Compar-
ison In-
progress Flag
PV Overflow/
Underflow Flag
Reserved
Phase Z Input
Reset Flag (ON
for one cycle)
Absolute No. of
Rotations Read
Error Flag
Absolute No. of
Rotations Read
Completed
Flag
Measuring Flag
(measurement
mode 1 or 2)
High-speed
Counter Oper-
ating Flag
Count Latched
Flag
Reserved
Absolute Off-
set Preset
Error Flag
Reserved
OFF: Target value comparison is not being performed for
CTBL(882).
Note This flag is always OFF for range comparison.
ON: Target value comparison is being performed for CTBL(882).
Note Target comparison is continued without interruption once it
has been started (as opposed to range comparison), so this flag
can be used to check whether target comparison is in progress.
OFF: There is no counter overflow or underflow in Linear Counter
Mode. This flag will always be OFF in Circular Counter Mode.
ON: There is a counter overflow or underflow in Linear Counter
Mode. The counter PV will be fixed at the overflow or underflow
limit. This flag will be cleared when the High-speed Counter Start
Bit is turned OFF.
---
ON for one cycle when the counter PV is reset with the counter
reset method set to a phase Z + software reset.
Note This flag will turn ON for one cycle after the counter PV is
reset if the phase Z signal (reset input) turns ON while the High-
speed Counter Reset Bit (A610.01) is ON.
OFF: No error
ON: Error
OFF: Rotations being read or reading has not been executed.
ON: Reading has been completed (Turned ON when serial recep-
tion of the number of rotations has been completed.)
OFF: Changes in the counter PV or the counter frequency is not
being measured.
ON: Changes in the counter PV or the counter frequency is being
measured.
In measurement mode 1, this flag will turn ON at the beginning of
the sampling time after the Measurement Start Bit (A610.02) is
turned ON.
Note Valid when Counter Data Display in System Setup is set to
Counter Movements (mode 1) or Frequency (mode 2).
OFF: Counter is not operating.
ON: Counter is operating.
OFF: Count has not been latched.
ON: Latching the count has been completed for the latch input.
---
OFF: No error occurred when saving the absolute offset.
ON: An error occurred when saving the absolute offset.
---
Function
Appendix C
Module
Controlled
by