XW2Z-100J-B9 Omron, XW2Z-100J-B9 Datasheet - Page 376

no-image

XW2Z-100J-B9

Manufacturer Part Number
XW2Z-100J-B9
Description
SERVO DRV+G8R CONNECTING CABLES
Manufacturer
Omron
Datasheet

Specifications of XW2Z-100J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z100JB9
Auxiliary Area Allocations
Address
A559
A560
A561
A562
A563
A564
A565
00 to 15 Number of Analog Samples
00 to 15 Analog Output 1 Output Value
00 to 15 Analog Output 2 Output Value
00
04
08
12
14
00
04
08
12
14
00
00
Bits
Analog Output 1 Flags
Analog Output 2 Flags
Analog Output 1 Conversion Enable Bit
Analog Output 2 Conversion Enable Bit
Name
User Adjustment
Completed
Operating
Output SV Error
Factory Adjust-
ment Value
Error
User Adjustment
Value Error
User Adjustment
Completed
Operating
Output SV Error
Factory Adjust-
ment Value
Error
User Adjustment
Value Error
Indicates the number of data samples actually input since sam-
pling started.
When an END refresh is selected, the 4-digit hexadecimal value
set here by the user is output from analog output port 1.
When immediate refreshing is selected, the 4-digit hexadecimal
value being output from analog output port 1 is stored here for
monitoring. The output value range depends on the output range,
as shown below.
• 0 to 10 V, 0 to 5 V or 1 to 5 V: FF38 to 1068 hex
• − 10 to 10 V: EA84 to 157C hex
Note
1. Set the analog output method (END or immediate refreshing)
2. Specify the output range with the output 1 setting.
This word has the same settings as the analog output 1 output
value (A560), above. (When an END refresh is selected, set the
value to output from analog output port 2. When an immediate
refresh is selected, the output value is stored here for monitoring.)
Note
1. Set the analog output method (END or immediate refresh) with
2. Specify the output range with the output 2 setting.
Initial value is 0.
Set to 1 if user performs offset/gain adjustment and Returns to
factory default setting of 0 if adjustment value is cleared.
ON: ON while the analog output is being changed by ACC(888).
OFF: Turned OFF when target value is reached.
ON: ON when the output SV setting is outside of the allowed set-
ting range.
OFF: OFF when the output SV is within range.
ON: ON when the factory-set data stored in flash memory is
invalid.
OFF: OFF when the factory-set data stored in flash memory is
normal.
ON: ON when the user-set adjustment value stored in flash mem-
ory is invalid.
OFF: OFF when the user-set adjustment value stored in flash
memory is normal.
Same as for Analog Output 1 Flags.
ON: Enables D/A conversion (enables analog output).
OFF: Disables D/A conversion (analog values output according to
Output Stop Function specification in System Setup).
Note This bit is cleared when the Modules operating mode is
changed between RUN or MONITOR mode and PROGRAM
mode.
ON: Enables D/A conversion (enables analog output).
OFF: Disables D/A conversion (analog values output according to
Output Stop Function specification in System Setup).
Note This bit is cleared when the Modules operating mode is
changed between RUN or MONITOR mode and PROGRAM
mode.
with the System Setup’s output method setting. A setting of 0
hex specifies an END refresh. This setting applies to both ana-
log output 1 and 2.
the System Setup’s output method setting. A setting of 0 hex
specifies an END refresh. This setting applies to both analog
output 1 and 2.
Function
Appendix D
353