XW2Z-100J-B9 Omron, XW2Z-100J-B9 Datasheet - Page 251

no-image

XW2Z-100J-B9

Manufacturer Part Number
XW2Z-100J-B9
Description
SERVO DRV+G8R CONNECTING CABLES
Manufacturer
Omron
Datasheet

Specifications of XW2Z-100J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z100JB9
Analog Outputs
Specified Output Values and Analog Output Signals
7-10-4 Applicable Instructions
END Refreshing
With Immediate
Refreshing
228
Analog output signal
−10 to 10 V
Analog output signal
0 to 5 V
+11.0 V
+10.0 V
−10.0 V
−11.0 V
−0.25 V
5.25 V
0.0 V
5.0 V
0.0 V
EA84
FF38
EC78
0000
Resolution: 4,000
Resolution: 10,000
0000
1388
0FA0
157C
1068
Set the analog output values in A560 and A561 using an instruction such as
the MOV instruction.
Outputs can be controlled with SPED(885) and ACC(888) as outlined below.
SPED(885) can be used to change the output value in steps.
(@) SPED
Specified output value
(4-digit Hex)
Specified output value
(4-digit Hex)
#0000
P
F
P: Port specifier
M: Always #0000
F: Analog output value
(#0001 for analog output 1 or #0002 for analog output 2)
0 to 10 V
Analog output signal
−0.5 V
10.5 V
10.0 V
0.0 V
1 to 5 V
Analog output signal
5.2 V
5.0 V
1.0 V
0.8 V
FF38
FF38
0000
0000
Resolution: 4,000
Resolution: 4,000
0FA0
0FA0
1068
1068
Specified output value
(4-digit Hex)
Specified output value
(4-digit Hex)
Section 7-10