PSB2163T-V31TR Infineon Technologies, PSB2163T-V31TR Datasheet - Page 269

no-image

PSB2163T-V31TR

Manufacturer Part Number
PSB2163T-V31TR
Description
IC AUDIO RINGING CODEC 28-PDSO
Manufacturer
Infineon Technologies
Series
ARCOFI®r
Datasheet

Specifications of PSB2163T-V31TR

Function
CODEC Filter
Interface
IOM-2, PCI, Serial
Number Of Circuits
1
Voltage - Supply
5V
Current - Supply
900µA
Power (watts)
1mW
Operating Temperature
-25°C ~ 80°C
Mounting Type
Surface Mount
Package / Case
DSO-28
Includes
Activation and Deactivation, B-Channel and D-Channel HDLC Controllers, D-Channel Priority Handler, Monitor Channel Handler
Lead Free Status / RoHS Status
Request inventory verification / Request inventory verification
Other names
PSB2163T-V31INTR
PSB2163T-V31TR
4
4.1
The ARCOFI-SP PSB 2163 is able to work in three different interface modes:
• IOM-2 TE interface (1.536 MHz)
• IOM-2 NON-TE interface (4.096 MHz)
• Serial control / serial data interface (SCI/SDI)
The ARCOS-SP PLUS supports each of these three interface modes in conjunction with
appropriate hardware. This chapter describes the different hardware setups. First the
ARCOFI-SP has to be connected to the particular hardware which must be configured
correctly. Then the ARCOS-SP PLUS software is called and informed about the
hardware configuration. With a click at the "Initialize Hardware" box the hardware is
checked and initialized for the use with ARCOS-SP PLUS. The ARCOFI-SP itself can be
located either on the SIPB 5133-SP evaluation board, inside a SIPB 5132-SP
telephone, or on a dedicated board like the SIPB 8051 telephone board. Also custom
specific boards with an IOM-2 interface are suitable.
In the "Show ARCOFI" window in the user area of ARCOS-SP PLUS, the following
modes can be set if the hardware support is enabled (compare with figure 1):
• Either the ICC/ISAC as a layer 1/2 device, or the EPIC/ELIC
• Either IOM interface mode, or SPI interface mode (SCI/SDI interface)
• Either A-Chip or B-Chip (only possible in IOM-2 interface mode)
These settings must correspond to the hardware that is connected to the PC on which
the ARCOS-SP PLUS software runs.
4.2
The ARCOS-SP PLUS software requires a specific SIPB 5000 hardware environment.
The firmware EPROM version 1.1 or newer must be installed on the SIPB 5000
mainboard. Three standard configurations are described in the next paragraphs. More
detailed information can be found in the technical description of the SIPB 5000 system.
Please note, that if the ICC-B is used as a layer-2 device, EPROM version 2.2 or newer
is required for the SIPB 5000 mainboard.
IOM-2 TE Interface with an ISAC-X
A common setup uses the SIPB 5100 (ISAC-S Module) or the SIPB 5103 (ISAC-P
Module) as layer 1/2 module. The ARCOFI-SP is connected via a SIPB 5130 (Audio
Module). Figure 6 shows the general setup either with an ISAC-S or with an ISAC-P
Module. The ARCOFI-SP is located inside a SIPB 5132-SP telephone, but instead of the
telephone any hardware which offers an IOM-2 interface can be connected.
Semiconductor Group
Hardware Setup for Use with ARCOS-SP PLUS
Introduction
Using the SIPB 5000 System
269
SIPO 2163