ATxmega192D3 Atmel Corporation, ATxmega192D3 Datasheet - Page 84

no-image

ATxmega192D3

Manufacturer Part Number
ATxmega192D3
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATxmega192D3

Flash (kbytes)
192 Kbytes
Pin Count
64
Max. Operating Frequency
32 MHz
Cpu
8-bit AVR
# Of Touch Channels
16
Hardware Qtouch Acquisition
No
Max I/o Pins
50
Ext Interrupts
50
Usb Speed
No
Usb Interface
No
Spi
5
Twi (i2c)
2
Uart
3
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
200
Analog Comparators
2
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
16
Eeprom (bytes)
2048
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.6 to 3.6
Operating Voltage (vcc)
1.6 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
5
Output Compare Channels
18
Input Capture Channels
18
Pwm Channels
18
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATxmega192D3-AU
Manufacturer:
CYPRESS
Quantity:
101
Part Number:
ATxmega192D3-AU
Manufacturer:
ATMEL
Quantity:
70
Part Number:
ATxmega192D3-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega192D3-AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega192D3-H
Manufacturer:
SQ
Quantity:
719
Part Number:
ATxmega192D3-MH
Manufacturer:
Atmel
Quantity:
565
8.4.2
8210B–AVR–04/10
Brown-Out Detection
The Brown-Out Detection (BOD) circuit monitors that the V
trigger level, V
low the trigger level for a minimum time, t
above the trigger level again.
Figure 8-4.
For characterization data on t
by a programmable BODLEVEL setting, see
Table 8-2.
Note:
The BOD circuit has 3 modes of operation:
• Disabled: In this mode there is no monitoring of the V
• Enabled: In this mode the V
recommended for applications where the power supply is stable.
for at least t
INTERNAL
TIME-OUT
1. The values here are nominal values only. For typical, maximum and minimum numbers consult
RESET
the device datasheet.
V
BOT
CC
Brown-out Detection reset.
Programmable BODLEVEL setting
BOD
. When the BOD is enabled, a BOD reset will be given if the V
will give a brown-out reset.
BODLEVEL[2:0]
111
110
101
100
011
010
001
000
BOD
CC
consult the device datasheet. The trigger level is determined
level is continuously monitored, and a drop in V
(1)
V
BOT-
BOD
Table
t
. The reset is kept active until the V
BOD
8-2.
CC
CC
level, and hence it is only
level is kept above a configurable
V
t
V
TOUT
BOT+
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
BOT
XMEGA D
CC
CC
level falls bel-
CC
below V
UNIT
level rises
V
BOT
84