PM7312 pmc-sierra, PM7312 Datasheet - Page 134

no-image

PM7312

Manufacturer Part Number
PM7312
Description
Freedm 32a1024l Assp Telecom Standard Datasheet
Manufacturer
pmc-sierra
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
PM7312-BI
Quantity:
46
Part Number:
PM73121-RI
Manufacturer:
PMC
Quantity:
8 000
Part Number:
PM73121-RI
Manufacturer:
PMC
Quantity:
8 000
Part Number:
PM73121-RI-P
Manufacturer:
PMC
Quantity:
20 000
Part Number:
PM73122-BI-P
Quantity:
32
Part Number:
PM73122-BI-P
Quantity:
977
Part Number:
PM73123-PI
Quantity:
33
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.
Document No.: PMC-2021833, Issue 2
Register 0x224: RHDL Maximum Packet Length
This register configures the maximum legal HDLC packet byte length.
MAX[15:0]
The maximum HDLC packet length (MAX[15:0]) configures the FREEDM 32A1024L to reject
HDLC packets longer than a maximum size when LENCHK is set high. Receive packets with
total length, including address, control, information and FCS fields, greater than MAX[15:0]
bytes are aborted. When LENCHK is set low aborts are not generated regardless of packet
length and MAX[15:0] must be set to ‘hFFFF.
Bit
Bit 31
To
Bit 16
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Type
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
FREEDM 32A1024L ASSP Telecom Standard Product Data Sheet
Function
Unused
MAX[15]
MAX[14]
MAX[13]
MAX[12]
MAX[11]
MAX[10]
MAX[9]
MAX[8]
MAX[7]
MAX[6]
MAX[5]
MAX[4]
MAX[3]
MAX[2]
MAX[1]
MAX[0]
Default
X
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Released