l-fw322-06-db ETC-unknow, l-fw322-06-db Datasheet - Page 35

no-image

l-fw322-06-db

Manufacturer Part Number
l-fw322-06-db
Description
Phy/link Open Host Controller Interface
Manufacturer
ETC-unknow
Datasheet
Data Sheet, Rev. 1
December 2005
Internal Registers
Power Management Control and Status Register
The Power Management Control and Status register implements the control and status of the PCI power
management function. This register is not affected by the internally generated reset caused by the transition from
the D3hot to D0 state. The value of this register after a PCI reset is dependent on whether the FW322 is enabled
to generate a PME event while in the D3cold state. If the PME_D3cold bit within the Power Management
Capabilities register is asserted, then the PME_STS and PME_ENB bits within this register will not be reset by a
PCI reset, i.e., these bits will become sticky bits. Otherwise these bits, along with all the other bits within this
register, will be reset by a PCI reset.
Offset:
Default:
Type:
Reference:
Table 17. Power Management Control and Status Register Description
Agere Systems Inc.
14:13
12:9
Bit
7:5
3:2
1:0
15
8
4
0000h (If PME_D3cold is deasserted)
Read/write
PCI Bus Power Management Interface Specification, Rev. 1.1, Section 3.2.4 and 1394 Open Host
Controller Interface Specification, Rev. 1.1, Section A.3.8.4
48h
DATA_SELECT
XX00h (If PME_D3cold is asserted)
DATA_SCALE
PWR_STATE
Field Name
DYN_DATA
PME_ENB
PME_STS
Reserved
Reserved
(continued)
Type
RW PME Enable. This bit enables the function to assert PME. If this bit is
RW Power State. This 2-bit field is used to set the FW322 device power
RC This bit is set when the FW322 would normally be asserting the PME
R
R
R
R
R
signal, independent of the state of the PME_ENB bit. This bit is
cleared by a writeback of 1, and this also clears the PME signal driven
by the FW322. Writing a 0 to this bit has no effect. This bit is imple-
mented as sticky when PME_D3cold is asserted in the Power
Management Capabilities register.
This 2-bit field indicates a scaling factor that is to be used when inter-
preting the value of the PM_DATA register within the Power Manage-
ment Extension register. The value and meaning of this field will vary
depending on the value that has been selected by the DATA_SELECT
field.
This 4-bit field is used to select which data values are to be reported
through the PM_DATA field in the Power Management Extension
register and the DATA_SCALE fields. Valid values are 0—7, which
map to power consumption/dissipation ratings for the FW322 within
the PM_DATA/DATA_SCALE fields.
cleared, then assertion of PME is disabled. This bit is implemented as
sticky when PME_D3cold is asserted in the Power Management
Capabilities register.
Reserved. Bits 7:5 return 0s when read.
Dynamic Data. This bit returns 0 when read, since the FW322 does
not report dynamic data.
Reserved. Bits 3:2 return 0s when read.
state and is encoded as follows:
00 = current power state is D0.
01 = current power state is D1.
10 = current power state is D2.
11 = current power state is D3.
PCI PHY/Link Open Host Controller Interface
Description
FW322 06 1394a
35